Operating Status

LED Sequence ( ) = fl ash, (__) = off

Description of repeated sequences

Normal (no failure)

Permanently lit

Power Fail
(i.e. switch off )

Short 50 ms fl ash + 950 ms pause

High Temperature
signal attenuation

750 ms fl ash + 250 ms pause

Over Temperature
main SMPS off

250 ms fl ash + 750 ms pause

DC
reason unknown

250 ms fl ash + 250 ms pause

DC
input-signal-fault

3 * fl ashing + 0.5 s pause

DC
fault in driver stage

4 * fl ashing + 0.5 s pause

DC
output stage defect

5 * fl ashing + 0.5 s pause

Output Stage Defect

without DC

6 * fl ashing + 0.5 s pause

Main SMPS off
(unless high temperature/
power fail)

2 * fl ashing + 0.5 s pause

6 TROUBLESHOO

TING

USER MANUAL
VORTEX 6, 4, 2.6 and 200V

P.25

6.1 On LED Flashing Sequences

When switching on the amp the On LEDs fl ash twice accompanied by a fl ash of
Clip LEDs. This is normal for the ‘Start’ sequence of the VORTEX.

When switching off the amp the On LEDs fl ash several times followed by a
fl ash of Clip LEDs. This is normal for the ‘Shut Down’ sequence of the VORTEX.
(It is the same as the loss of the mains voltage.)

In the following table you will fi nd the possible LED sequences of the On LEDs:

Examples of LED Sequences
LED sequence:

Channel 1 :

Channel 2 :

Malfunction:

Channel 1: high temperature with signal attenuation

Channel 2: normal operation

LED sequence:

Channel 1 :

Channel 2 :

Malfunction:

Channel 1: DC, output stage defect

Channel 2: main SMPS off