mode is useful when, for example, 3 identical loudspeakers are to be operated

with the same power.

3.9.4 Mono-Bridge Operation

One-channel mono bridged operation.

The second channel processes the same input signal, but with reversed phase.

The (single) load is connected between the two positive channel outputs using

a suitable connected SPEAKON connector. While the total output of the ampli fi er

remains the same, both the available output voltage and the minimum impedance

that can be connected are doubled, as compared with stereo operation. Only

channel A-Input is active – turn the volume on channel B down to zero.

WARNING !

In Mono-Bridge mode RMS output voltages are as high as 230 V. Wiring

to the speaker loads must conform to NEC Class 3 safety standards or its

equivalent that meets all national and local electric codes.

All customer specifi c cables may only be manufactured by qualifi ed

suppliers/personnel. All cabeling or rewiring work must be carried out by

qualifi ed personnel.

*Z

min

= 2

Ω for VORTEX 6, 4 and 2.6

*Z

min

= 4

Ω for VORTEX 200V

3.9.5 SPEAKON Connection

Both SPEAKON connectors are connected to channel A and channel B outputs.

The pin confi guration of the SPEAKON-connectors is as follows:

Upper SPEAKON:

Pin 1+

Channel A signal

Pin 1-

Channel A ground

Pin 2+

Channel B signal

Pin 2-

Channel B ground

Bottom SPEAKON:

Pin 1+

Channel B signal

Pin 1-

Channel B ground

Pin 2+

Channel A signal

Pin 2-

Channel A ground