discrepancy or to obtain necessary parts to replace any missing or damaged components. TABLE 2
provides a gas log kit part’s list for both natural gas and propane kits. Use the appropriate version of
TABLE 2 as a check sheet while verifying the presence and condition of each kit part. Again, contact
Country Flame or an authorized dealer to resolve any issues before converting the Inglenook gas log set to a
different fuel.


LIQUID PROPANE CONVERSION KIT

ITEM QTY

PART

NUMBER

ITEM DESCRIPTION

Regulator 1

GC-3905-01

SIT 820 NOVA mV Gas Valve

Pilot 1

BV-4613

#51 DMS Pilot Injector Orifice

Front Spud Orifice

1

IN-6513

#31 DMS NG Front Orifice Spud

Rear Spud Orifice

1

IN-6514

#43 DMS NG Rear Orifice Spud

Conversion Label

1

IN-6521

Conversion LP to NG

Instructions 1

IN-6523

Conversion Kit Instructions

TABLE 2a: IN-6504 CONVERSION KIT (to natural gas)


NATURAL GAS CONVERSION KIT

ITEM QTY

PART

NUMBER

ITEM DESCRIPTION

Regulator 1

GC-3906-01

SIT 820 NOVA mV Gas Valve

Pilot 1

BV-4614

#35 DMS Pilot Injector Orifice

Front Spud Orifice

1

IN-6515

#48 DMS LP Front Orifice Spud

Rear Spud Orifice

1

IN-6516

#55 DMS LP Rear Orifice Spud

Conversion Label

1

IN-6522

Conversion NG to LP

Instructions 1

IN-6524

Conversion Kit Instructions

TABLE 2b: IN-6503 CONVERSION KIT (to propane)


It should be noted that conversion from one type of fuel to another type of fuel requires the adjustment of
both the front and rear burner air shutters. Refer to the specifications in this manual and verify local codes
and other site-specific conditions to ensure proper setting of all parameters involved in the fuel conversion
process.

ALTITUDE LIMITATIONS

In the United States, the Inglenook gas log input ratings are determined at sea level operation. The
Inglenook gas logs do not require any operational changes up to and including 610 meters. Gas log
operations above 610 meters require the Inglenook burners to be set as stated in TABLE 3. Exception: As
permitted by the authority having jurisdiction.

Canadian input ratings of this unit are determined at seal level operation. No Inglenook input rating needs
to be change up to 4,500 feet above sea level in Canada. Installation of the Inglenook gas logs at altitudes
above 4,500 feet is subject to field test of the individual installation and approval by the local authority