Country Flame INGLS 24-N User Manual

Page 11

Advertising
background image

Version 1.0b

11

INGLENOOK GAS LOG KIT SPECIFCATIONS

TABLE 3 provides specifications for both Inglenook natural gas and propane gas fuel log kits. The installer
and homeowner must understand the differences in these kits both for the type of fuel being used and the
impact that altitude has on specific fuel operations. Test procedures for verifying the fuel pressures are
provided as part of the SIT 820 control valve operation provided in this manual. Contact a local authorized
dealer or Country Flame direct to resolve any issues with specifications or the requirements thereof.

TABLE 3:

INGLENOOK LOG SET SPECIFICATIONS

DESCRIPTION NATURAL

GAS

PROPANE

GAS

INPUT RATING (Btu/hr) 0 - 610 Meters*

65,000 65,000

MIN INPUT RATING (Btu/hr) 0 – 610 Meters

42,600 43,000

ORIFICE SIZE (DMS) 0 – 610 Meters front/rear

31/43 48/55

MINIMUM SHUTTER SETTING (inches)

0 1/8

PILOT ORIFICE (DMS)

51 35

INPUT RATING (Btu/hr) 610 – 1370 Meters

59,000 58,700

ORIFICE SIZE (DMS) 610 – 1370 Meters

32/44 49/56

MANIFOLD PRESSURE (Inches of Water Column)

3.5 10.0

MANIFOLD PRESSURE, Low Setting (Inches of W.C.)

1.4 4.2

MINIMUM INLET PRESSURE (Inches of W.C.)

4.5 11.0

MAXIMUM INLET PRESSURE (Inches of W.C.)

7.0 14.0

*ANSI standards are SAFETY STANDARDS not PERFORMANCE STANDARDS. Performance standards are defined as
efficiency standards, A.F.U.E ratings, and efficiency test protocol that is established by the United States Department of Energy.

SHUTTER SETTING

Verify that the adjustable burner air shutter is set according to TABLE 3. FIGURE 4 shows the rear burner
assembly (Item B) and the adjustable burner air shutter (Item A). Loosen the locking screw that holds the
air shutter in place. Use a proper sized drill bit shank to set the correct opening of the air shutter. Retighten
the locking screw. To set the burner air shutter for the front burner assembly, repeat the process.

FIGURE 4: ADJUSTABLE BURNER AIR SHUTTER

Advertising