Troubleshooting Guide (cont’d)

HIGH TEMPERATURE SHUT OFF SYSTEM

This water heater is equipped with an automatic gas shut off sys­

tem. The high temperature shut off is built into the gas control

valve. This system shuts off the gas supply to the water heater
burners when high water temperatures are present. It is non­
resettable. If the high temperature shut off activates, the gas con­
trol valve must be replaced. If this were to occur, turn “OFF” the

entire gas supply to the water heater. Contact the Sears Service
Center,

AWARNING

Should overheating occur or the gas supply foil to shut off,
turn “OFF” the manual gas control valve to the appliance.

AWARNING

Due to the nature of the typicai gas water heater, the
water temperature in certain situations may be hotter
than the thermostat setting.
Shor^ ft^uent draws of hot water - especiaiiy with very

cold incoming water - can shock the thermostat into brief

operation resulting in hotter and hotter layers of water
closer to the top of the tank.
Changes in hot water usage patterns or raising the tem­
perature differential between the cut-on of tiie thermo­
stat and the cold water temperature vtill usually eliminate

the problem.

NOT ENOUGH OR NO HOT WATER

• Check the manual gas shut off valve to be sure it is open.
• Check the pilot flame. It may have gone out. All models have

an opening behind the outer door for viewing the pilot.

If the pilot is not lit, follow the “Lighting” instructions in this

manual or located above the gas control valve on the water

heater to relight the pilot. If the water was extremely hot and is
now cold, the high limit safety temperature shut off may have
put out the burner and pilot. If the high temperature shut off

activates, the gas control wilve must be replaced. Contact the

Sears Service Center.

• The gas control knob must be turned to the “ON” trosition.

The temperature adjustment dial may be set too low. See the

“Temperature Regulation” section.

• The gas company can check the gas input to see if it is correct.

An underfired water heater will not heat water as quickly.

Look for leaking or open hot water faucets. Make sure all arc

closed.

The cold water inlet temperature may be colder during the

winter months. It will take longer ro heat the water and seem
like less hot water.

If you cannot find what is wrong, call the Sears Service

Center.

WATER IS TOO HOT

• The temperature adjustment dial may be set too high. See the

“Temjierature Adjustment” section.

NOTE: A period of time is necessary after an adjustment
has been inade for the water temperature to teach the new
temperature setting.

• If lower temperature settings will not lower the water tempera­

ture, call the Sears Service Center.