Safety Precautions
AWARNING
The water heater with draft hood installed must be prop
erly vented to a chimney which terminates outdoors.
Never operate the water heater unless it is vented to tfie
outdoors and has adequate air supply to avoid risks of
improper operation, explosion or aspiration.
AWARNING
Minimum clearances between the water heater and com
bustible construction are I" at the sides and rear,
A"
at the
front, Md 6" the vent pipe. Clearance from the top
of the jacket is 18" on most models. Note that a lesser
dimension may be allowed on some models. Refer to the
label on the water heater adjacent to the gas control valve
for all clearances.
acaution
WATER HEATERS EVENTUALLY LEAK: Installation of
the water heater must be accomplished In such a manner
that If the tank or any connections should leak, the flow of
water vdll not cause damage to the structure. When such
locations cannot be avoided, a sultaUe drain pan should
be installed under the water heater. Drain pans are avail
able at your local Sears store. Such a drain pan must be
not greater than I
'A
inches deep, have a minimum length
and width of at least 2 inches greater than the water
heater dimensions and must be piped to an adequate
drain. The pan must not restrict combustion air flow.
Under no circumstances is the manufecturer or Sears to
be held liable for any water damage in connection with
this water heater.
_______________ AWARNING__________________ _
Do not use this appliance if any part of it has been under
water. Immediately call a Sears Service Technician to
inspect the appliance and to replace the gas control or any
part of the burner system which has been under water.
AWARNING
HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of
time (generally two weeks or more). Hydrogen gas is
ex^mely flammable and explosive. To prevent the possi
bility of Injury under these conditions, we recommend the
hot vrater faucet be opened for severd minutes at the
kitchen sink before any electrical appliances which are
connected to the hot water system are used (such as a dis
hwasher or washing machine). If hydrogen gas is present,
there will probably be an unusual sound similar to air
escaping through the pipe as the hot water faucet is
opened. There must be no smoking or open flame near
the faucet at the time it is open.
AWARNING
INSULATING JACKETS: When installing an external
water heater insulation jactet on a gas water heater:
• DO NOT cover the temperature-pressure relief valve.
• DO NOT put insulation over any part of tiie top of the
gas mter heater.
• DO NOT put insulation over the gas control valve or gas
control valve/bumer cover, or any access areas to the
burner.
■ DO NOT let insulation around the gas water heater to
get within 8 inches of the floor (air must get to the
burner).
• DO NOT cover or remove operating instructions, and
safety related warning labels and materials affixed to the
vntter heater.
Failure to heed this will result in the possibility of a fire or
explosion.