Troubleshooting Guide (cont’d)
Leakage Checkpoints
he water
Use this guide to check
a
Leaking" water heater. Many suspect
ed Leakers arc not Icahine tanks. Often the source of the
can be found and correctetT
If you ^ not thoroughly fkmiliar with your local gas codes your
water heater, and safety practices, contact the Sears .Service
Center to check the water heater.
acaution
Read this manual first. Then before checking the water
*** *“Pply has been turned
OFF , and never turn the gas “ON” before the tank is
completely foil of water.
acaution
Never use this water heater unless it is completely filled
with water. To prevent damage to the tank, the tank
must be filled with water. Water must flow from the hot
water faucet before turning “ON” gas to the water
heater.
e
Water at the draft hopd is water vapor which has
œndensed out of the combustion products. This is caused
by a problem in the vent. Contact the Scars Service Center
‘Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
*The primary anode rod fitting may be leaking.
Small amounts of water from tcmpicrature-pressure relief
valve may be due to thermal expansion or high water
pressure in your area.
*The temperature-pressure relief valve may be leaking at
the tank fitting.
e
Water from a drain valve may be due to the valve opened
slightly.
© *Thc drain valve may be leaking at the tank fitting.
Combustion products contain water vapor which can
condense on the cooler surfaces of the tank. Droplets
form and drip into the fire or run on the floor. This is
common at the time of startup after installation and when
incoming water is cold.
Water in the water heater bottom or on the floor may be
from condensation, loose connections, or the relief valve.
E>0 NOT replace the water heater until a fiill inspection
of all possible water sources is made and necessary
corrective steps taken. Leakage from other appliances,
water lines, or ground seepage should also be checked.
NOTE! To check where threaded portion enters tank,
insert cotton smd) between jacket opening and fitting.
If cotton is wet, follow “Draining” instructians in the
Service and Adjustment” section and then remove
fitting. Put pipe dope or teflon tape on the threads
Md replace. Tlien follow “Filling the Water Heater”
instructions in the “Installation Instructions” section.
©