BYPASS VALVES

Bypass valve(s) should always remain In soft water
service position. Position in “bypass” only if needed for
softener repairs.

SINGLE BYPASS

Inches

CM

A

Salt Tank Height

40-1/4

102.2

B

Resin Tank Diameter
(nominal)

9

22.9

C

Resin Tank Height (nominal)

40

101.6

D

Inlet-Outlet Height

41-1/2

105.4

E

Overall Height

47-3/4

121.3

Fi Length

19-3/4

50.2

F2 Width

16-1/2

41.9

-

Distance between inlet-outlet
centerlines

3-3/4

8.6

MODEL 383760 TIMER CODE H32

MODEL 393760 TIMER CODE H 33

Bypass

valve

Inlet

valve

FIG. 57

WATER SUPPOr TO WATER SOFTENER

MODEL 38376

MODEL 39376

Minimum water system flow (gpm)

3

3

Minimum-maximum water pressure (psi)

20 - 125

20 - 125

Minimum-maximum water temperature (°F)

40 - 120

40 - 120

Maximum water hardness (gpg)

110

110

Maximum “clear water” iron (ppm)*

10

10

SALT FOR WATER SOFTENER

Type of salt needed

nugget

nugget

Alternate type of salt

pure, evaporated, compacted

water softener salt

pure, evaporated, compacted

water softener salt

gpm = gallons per minute gpg = grains per gallon

psi = pounds per square inch ppm = parts per million

* Capacity to remove clear water iron is substantiated by WQA test data. State of Wisconsin requires additional treatment if water supply contains
greater than 5 ppm clear water iron.

Questions? Call The Kenmore Water Line 1-800-426-9345