Troubleshooting, Valve position indicators, Timer pwa replacement – Kenmore INTELLISOFT 625.38376 User Manual

Page 37: Fig. 64, Service tech information

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Service Tech Information

TROUBLESHOOTING

VALVE POSITION INDICATORS:

Depending on the valve position, the following indica­

tors show in the display:

Indicator

Valve Position

Serv................................... Service
Fill...................................... Fill
Brine.................................. Brining/Brine Rinse
Bkwsh................................ Backwash
Rinse..................................Fast Rinse

When the valve Is rotating from one cycle to another,

both Indicators flash. For example. If the valve Is In

transition between fill and brining, both

Fill and Brine

flash. Upon reaching brining position. Fill goes off and

Brine Is on steady. The time display shows the minutes
of the cycle remaining.

NOTE: If the faceplate is left in a diagnostic display
(or a flashing display when setting times or hard­
ness), present time automatically returns if a button

is not pressed within 4 minutes. To return to the
diagnostic display, repeat step 1.

OTHER INFORMATION

While In this diagnostic screen, the following Information

Is available and may be beneficial for various reasons.

This information is retained by the computer from the
first time electrical power Is applied to the faceplate.

• Press and hold the UP button to display the number of

days this faceplate has had electrical power applied.

• Press and hold the DOWN button to display the num­

ber of regenerations Initiated by this faceplate since

the code number was entered.

• Press the RECFIARGE button to advance the valve to

each position and observe the switch and position
Indicators to verify component operation, or to possi­
bly Isolate a defect.

• Press and hold the SELECT1 button for 3 seconds

until either FI 32 or FI 33 shows In the display, see Fig.
64.

This code Identifies the softener nominal capacity
size. If the wrong number shows, the softener will
operate on Incorrect programming. Do the following as

needed.

H 32 or H 33 does show:

Press the SELECT 1 button

to return to the present time display.

To change number:

Press the UP or DOWN button

until the correct code shows. Then, press the
SELECT1 button and reset the timer.

Valve Outlet

FIG. 62

TIMER PWA REPLACEMENT

Be sure the valve is in service position when replac­
ing the timer PWA (observe valve cycle indicator).

If

after Installing and programming the replacement timer
PWA, the valve Is not In service position, do the following
to assure correct cycle orientation, or timing, between the
faceplate and valve.

Use the MANUAL ADVANCE procedures with the
RECFIARGE NOW button, advance through the recharge
cycles until the valve stops In service position, and
RECFIARGE no longer flashes In the display.

NOTE: The valve motor may automatically drive

through several valve positions while searching for

service. If an error code occurs, unplug the trans­

former, then plug in again.

Model 38376

Model 39376

FIG. 64

Questions? Call The Kenmore Water Line 1-800-426-9345

37