Service Tech Information

The faceplate timer (PWA) computer has a self-diagnostic
function for the electrical system, except put power and
water meter. The computer monitors electronic components
and circuits for correct operation. If a malfunction occurs, an
error code appears in the faceplate display.

The chart below shows the error codes that could appear,
and the possible problems for each code.

FIG. 60

POSSIBLE PROBLEM

CODE

MOST LIKELY

LESS LIKELY

Erri, ЕггЗ, Err4

wiring harness connections at switch and facepiate not connected / position switch inoperabie / motor inoperabie

Err5

facepiate timer (PWA)

While an error code appears in the display, all faceplate

buttons are inoperable except the SELECT1 button.
SELECT 1 remains operational so the service person can
make the MANUAL INITIATED ELECTRONIC DIAGNOS­

TICS (below) to further isolate the problem, and check the
water meter.

PROCEDURE FOR REMOVING ERROR CODE

FROM FACEPLATE:

1. • Unplug transformer from outlet.

• Plug in transformer.
• Wait for 8 minutes.

2. • Unplug transformer from outlet.

• Correct problem.
• Plug in transformer.
• Wait for 8 minutes.

The error code will return if the problem was not corrected.

MANUAL INITIATED ELECTRONICS DIAGNOSTICS:

To enter diagnostics, press the SELECT1 button and hold
for three seconds. The display will show valve cycle posi­
tion, position switch status (open or closed), and turbine
operation. See Fig. 59.

TURBINE OPERATION;

If no water is flowing through the

softener, the turbine indicator displays three zeros. When
water is flowing, the flow bar scrolls across the display, and
a 000 to 140 count repeats for each gallon of water passing
through the turbine. To check for positive operation of the
turbine if zeros are shown, open a nearby soft water faucet
and observe the turbine count and flow bar. If you don’t get
a reading in the display, with faucet open, pull the sensor
from the valve outlet port. Pass a small magnet back and
forth in front of the sensor. You should get a reading in the
display. If you get a reading, unhook the in and out plumb­
ing and check the turbine for binding.

POSITION SWITCH STATUS:

With the valve in service, or

any of the recharge cycles, the switch indicator will show
open, while the valve is rotating from one position to anoth­
er, the indicator will show the switch closed. A defect is
probable if indications vary from this pattern.

valve position indicator

number of days

since the last

regeneration

water meter
turbine count

position switch

indicator (open)

VALVE IN SERVICE POSITION

valve position indicator

Ml. II U

LOCU

m'lE REMAINING

I

HDD

U J J ^

minutes of fill

. cycle remaining

- water meter

turbine count

position switch

indicator (open)

VALVE IN RECHARGE POSITION (FILL, IN THIS EXAMPLE)

valve position indicator

(Fill and Brine Flashing)

y___________ minutes of brining
'

.

.-..-1

- time (begins to count

II II L

BRINE

lUU

TIME REMAINING

I

nnrL

UIJU>',

down when valve

reaches brining

position)

water meter
turbine count

position switch

indicator (closed)

VALVE ROTATING FROM ONE RECHARGE POSITION TO

ANOTHER (FROM FILL TO BRINING IN THIS EXAMPLE)

FIG. 61

Questions? Call The Kenmore Water Line 1-800-426-9345

36

Advertising