A

WARNING

Breathing Hazard - Carbon Monoxide Gas

Install water heater in accordance

with the instruction manuai and
NFPA 54.

To avoid injury, combustion and
ventilation air must be taken from
outdoors.

Do

not

place

chemical

vapor

emitting

products

near

water

heater.

Breathing carbon monoxide can cause brain damage or

death. Always read and understand instruction manual.

Energy Conservation Act standards with respect to insulation

and standby loss requirements, making an insulation blanket

unnecessary.

A WARNING

Breathing Hazard - Carbon Monoxide Gas

Do not obstruct water heater air
intake with insulating blanket.

Gas and carbon monoxide

detectors are available.

Install water heater in accordance

with the instruction manual.

Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.

A gas water heater cannot operate properly without the correct

amount of air for combustion, see Figure 9. Do not install in a

confined area such as a closet, unless you provide air as shown
in the

Locating The New Water

Heater section. Never obstruct

the flow of ventilation air. If you have any doubts or questions at

all, cal! your gas supplier. Failure to provide the proper amount

of combustion air can result in a fire or explosion and cause
death, serious bodily injury, or property damage.

4 12" MAX. (30 cm)

T

VENTILATION

AIR

OPENING O

t

F£CT/liN(^LAR

3"

AIR DUCT

(76.

' MIN.

AIR DUCT

”^12" MAX.

(30 cm)

FRONT VIEW

T

OF DOOR

FIGURE 9.

If this water heater will be used in beauty shops, barber shops,
cleaning

establishments,

or

self-service

laundries

with dry

cleaning equipment, it is imperative that the water heater or

water heaters be installed so that combustion and ventilation
air be taken from outside these areas.

Propeliants

of

aerosol

sprays

and

volatile

compounds,

(cleaners,

chlorine

based

chemicals,

refrigerants,

etc.)

in

addition to being highly flammable in many cases, will also
change to corrosive hydrochloric acid when exposed to the
combustion products of the water heater. The results can be
hazardous, and also cause product failure.

Insulation Blankets

Insulation blankets available to the general public for external
use on gas water heaters are not necessary with Kenmore

products. The purpose of an insulation blanket is to reduce the
standby heat loss encountered with storage tank heaters. Your
Kenmore water heater meets or exceeds the National Appliance

Ak WARNING

Should you choose to apply an insulation blanket to this heater,

you

should

follow

these

instructions

(See

Figure

1

for

identification of components mentioned below). Failure to follow

these instructions can restrict the air flow required for proper
combustion, potentially resulting in fire, asphyxiation, serious

personal injury or death.

• Do not apply insulation to the top of the water heater, as this

will interfere with sate operation of the draft hood.

• Do not cover the outer door, thermostat or temperature &

pressure relief valve.

• Do not allow insulation to come within 2” (50.8 mm) of the

floor to prevent blockage of combustion air flow to the burner.

• Do not cover the instruction manual. Keep it on the side of

the water heater or neaitiy for future reference.

• Do obtain new warning and instruction labels from Sears

for placement on the blanket directly over the existing labels.

• Do inspect the insulation blanket frequently to make certain

it does not sag, thereby obstructing combustion air flow.

Combustion Air and Ventilation for
Appliances Located in Unconfined Spaces

UNCONFINED SPACE is space whose volume is not less than

50 cubic feet per 1,000 Btu per hour (4.8 m^ per kW) of the
aggregate input rating of ail appliances installed In that space.

Rooms communicating directly with the space in which the

appliances are installed, through openings not furnished with

doors, are considered a part of the unconfined space.

In unconfined spaces in buildings, infiltration may be adequate

to provide air for combustion, ventilation and dilution of flue

gases. However, in buildings of tight construction (for example,
weather stripping, heavily insulated, caulked, vapor barrier, etc.),
additional air may need to be provided using the methods
described in

Combustion Air and Ventilation for Appliances

Located in Confined Spaces.

10