Tank (sediment) cleaning, Vent system inspection, Tank (sediment) cleaning venting system inspection – Kenmore Power Miser 12 153.331413 HA User Manual

Page 20: Warning, Oanoer, Service and adjustment, Tank (sediment) cleaning burner inspection, Burner cleaning

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

SERVICE AND ADJUSTMENT

Tank (Sediment) Cleaning

Burner Inspection

Sediment build-up on the tank bottom may create varying
amount of noise, and if left in the tank will cause permanent

tank failure. In some water areas, you may not be able to drain

ali sediment deposits by simply draining the tank. In these
cases Mag-Erad (part no. 23600) can be used to help remove

the sediment deposits. This may be ordered from the Sears

Service Center. For ordering, refer to the

Parts Order List

section.

Vent System Inspection

A

WARNING

Cartoon Monoxide and Fire Hazard

Fiue gases may escape if vent pipe
is not connected.

Be alert for obstructed, sooted or
deteriorated vent system to avoid
serious injury or death.

Do not store corrosive chemicals
in vicinity of water heater.

Chemical corrosion ot flue and vent

system can cause serious injury or

death

Breathing carbon monoxide can cause brain damage or

death. Always read and understand instruction manuai.

At least once a year a visual inspection should be made of the

venting system. You should look for:

• Obstructions which couid cause improper venting. The

combustion and ventiiation air flow must not be obstructed.

Damage or deterioration which could cause improper

venting or leakage of combustion products.

Rusted flakes around top of water heater.

Be sure the vent piping is properly connected to prevent escape
of

dangerous

flue

gasses

which

could

cause

deadly

asphyxiation.

Obstructions

and

deteriorated

vent

systems

may

present

serious health risk or asphyxiation.

Chemical vapor corrosion of the flue and vent system may
occur if air for combustion contains certain chemical vapors.
Spray can propellants, cleaning solvents, refrigerator and air
conditioner

refrigerants,

swimming

pool

chemicals,

calcium

and sodium chloride, waxes, bleach and process chemicals
are typical compounds which are potentially corrosive.

If when inspecting the vent system you find sooting or
deterioration, something is wrong. Call the local gas supplier

to correct the problem and clean or replace the flue and venting

before resuming operation of the water heater.

Flood damage to a water heater may not be readily visible or
immediately detectable. However, over a period of time a

flooded water heater will create dangerous conditions which
can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY

DAMAGE. Contact a Sears Service Center to replace a flooded

water heater. Do not attempt to repair the unitl it must be

replaced!

At least once a year a visual inspection should be made of the

main burner and pilot burner. See Figure 23.

You should check for sooting. Soot

impair proper combustion.

is not normal and will

Soot build-up indicates a problem that requires correction
before further use. Turn “OFF” gas to water heater and
leave off until repairs are made, because failure to correct the

cause of the sooting can result in a fire causing death, serious

injury, or property damage.

Burner Cleaning

OANOER

Fire or Explosion Hazard

Failure to properiy reseal the combustion chaml»r will
disable the flammable vapor ignition resistance feature
of this water heater, which could result in death or serious
injury.

Contact

your

local

Sears

Service

Center

for assistance.

Read instruction manual before

installing, using or servicing

water heater.

In the event your burner needs cleaning, following these

instructions:

If inspection of the burner shows that cleaning is required, turn

the gas control knob clockwise (

r~\

) to the “OFF” position,

depressing slightly.

NOTE: The knob cannot be turned from “PILOT” to '
unless knob is depressed slightly. DO NOT FORCE.

‘OFF”

The burner needs to be removed for cleaning. Cal! the Sears

Service Center to remove and clean the burner and correct the
problem that required the burner to be cleaned.

20

Advertising
This manual is related to the following products: