Element cleaning/ replacement, Awarning, Service and adjustment (cont’d) – Kenmore Power Miser 12 153.320493 HT User Manual

Page 18

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Service and Adjustment (cont’d)

Element Cleaning/
Replacement

NOTE: These instructions are written for element cleaning
and element replacement for the lower element. If it is neces­
sary to clean or replace the upper element, then repeat these

instructions.

To remove the element from your tank in order to clean or

replace it:

1. Before beginning turn “OFF” the electric power supply to the

water heater.

AWARNING

HAZARD

OF

ELECTRICAL

SHOCK!

Before

removing

any access panels or servicing the water heater, make
sure the electrical supply to the water heater is turned
“OFF”. Failure to do this could result in DEATH, SERI­
OUS BODILY INJURY, OR PROPERTY DAMAGE.

2. Turn off the water supply to the water heater at the water

shutoff valve or water meter.

3. Attach a hose to the water heater drain valve and put the

other end in a floor drain or outdoors. Open the water heater

drain valve. Open a nearby hot water faucet which will relieve
pressure in the water heater and speed draining.

AWARNING

The water passing out of the drain valve may be extremely
hot To avoid being scalded, make sure all connections are tight
and that the water flow is directed aiway from any person.

4. Remove the two screws securing the access panel, and remove

panel.

5. After you have removed the lower access panel, remove the

adjustment

dial

from

the

thermostat

by

gently

pulling

it

directly away from the thermostat.

Q

6. Remove the insulation block to expose the opening.

18