Troubleshooting Guide (cont*d)

Operational Conditions

SMELLY WATER

In each water heater there is installed at least one anode rod (see
parts section) for corrosion protection of the tank. Certain water
conditions will cause a reaction between this rod and the water.
The most common complaint associated with the anode rod is
one of a “rotten egg smell”. This odor is derived from hydrogen
sulfide gas dissolved in the water. The smell is the result of four
factors which must all be present for the odor to develop:

a. a concentration of sulfate in the supply water.
b, little or no dissolved oxygen in the water.

c, a sulfate reducing bacteria within the water heater. (This

harmless bacteria is non-toxic to humans.)

d. an excess of active hydrogen in the tank. This is caused by

the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater
models by replacing the anode(s) with one of less active material,
and then chlorinating the water heater tank and all hot water
lines. Contact the local Sears Service Center for further informa­
tion concerning an Anode Replacement Kit #9001453 and this
Chlorination Treatment.

If the smelly water persists after the anode replacement and chlo­
rination treatment, we can only suggest that continuous chlori­
nation

and

filtering

conditioning

equipment

be

considered

to

eliminate the water problem.

Do not remove the anode leaving the tank unprotected. By
doing so, all warranty on the water heater tank is voided.

V\/R" IN HOT WATER FAUCETS

AWARNING

HYDROGEN GAS: Hydrogen gas can be produced in a
hot water system that has not been used for a long peri*
od of time (generally two weeks or more). Hydrogen gas
is extremely flammable and explosive. To prevent the
possibility of injury under these conditions, we recom­
mend the hot water faucet be opened for several min­
utes at the kitchen sink before any electrical appliances

which are connected to the hot water system are used
(such as a dishwasher or washing machine). If hydrogen
gas is present, there will probably be an unusual sound
similar to air escaping through the pipe as the hot water
faucet is opened. There must be no smoking or open
flame near the faucet at the time it is open.

RUMBLING NOISE

In some water areas, scale or mineral deposits will build up on

your heating elements. This buildup will cause a rumbling noise.

Follow

“Element

Cleaning/Replacement”

instructions

to

clean

and replace the elements.

HIGH TEMPERATURE SHUT OFF SYSTEM

The water heater has a high limit shut off system with a reset
button located on the thermostat.

Follow the resetting instructions which refer to the high limit
behind the access panel.

NOTE: If your water heater is connected to an “OFF PEAK”
clock, and uses the “3 wire lead” wiring diagram in the
“Wiring Diagram” section, then the water heater will have a
hi-limit on hoth the upper and lower thermostats. Follow

the instructions to reset the hi-limit behind the upper and

lower access panels.

• Before beginning, turn “OFF” electrical power supply to the

water heater.

AWARNING

HAZARD

OF

ELECTRICAL

SHOCK!

Before

removing

any access panels or servicing the water heater, make
sure the electrical supply to the water heater is turned
“OFF”. Failure to do this couid resuit in DEATH, SERI­
OUS BODILY INJURY, OR PROPERTY DAMAGE.