Service and Adjustment (contad)

7,

Lift out the tab as shown to unclip the terminal cover from

the

thermostat.

The

terminal

cover

can

now

be

removed

from the thermostat.

8.

Disconnect the two wires on the element and unscrew the

old element from the tank.

9.

Clean the area around the element opening. Remove any

sediment

from

or

around

the

element

opening

and

inside

the tank,

10. If you are cleaning the element you have removed, do so by

scraping or soaking in vinegar or a de-liming solution.

12.

Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is on the lower front
of the water heater.

13. Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open
when the water heater is in use.

14.

To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run

until a constant flow is obtained. This will let air out of the

water heater and the piping.

A CAUTION

Never use this water heater unless it is completely full of

water. To prevent damage to the tank and heating ele­

ment, the tank must be filled with water. Water must
flow from the hot water faucet before turning “ON”
power.

15.

16.

Check element for water leaks. If leakage occurs, tighten
element or repeat steps 2 and 3, remove element and reposi­

tion gasket. Then repeat steps 11 through 15.

Reconnect the two wires to the element and then check to
make sure the thermostat remains firmly against the surface
of the tank.

17. Replace the terminal cover on thermostat.

AWARNING

Replacement elements must (I) be the same voltage and
(2) no greater wattage than listed on the model rating
plate affixed to the water heater.

11.

A new gasket should be used in all cases to prevent a possi­

ble water leak. (See Element Gasket in the “Parts Order
List” Chart). Place the new element gasket on the thread
side of the cleaned or new element and screw into tank,
securing tightly using an element wrench.