CONNECTING THE WATER LINE

BEFORE YOU BEGIN

This water line installation is not warranted by the

refrigerator or icemaker manufacturer or retailer.
Follow these instructions carefully to minimize the
risk of expensive water damage.

Water hammer (water banging in the pipes) in house

plumbing can cause damage to refrigerator parts
and lead to water leakage or flooding. Call a

qualified plumber to correct water hammer before

installing the water supply line to the refrigerator.

To prevent burns and product damage, do not hook

up the water line to the hot water line.

If you use your refrigerator before connecting the

water line, make sure the icemaker power switch is

in the

Off (O)

position.

Do not install the icemaker tubing in areas where

temperatures fall below freezing.

When using any electrical device (such as a power
drill) during installation, be sure the device is double­

insulated or grounded in a manner to prevent the
hazard of electric shock, or is battery-powered.

If a

reverse osmosis water filtration system

is

connected to your cold water supply, this water line

installation is not warranted by the refrigerator or
icemaker manufacturer or retailer. Follow next
instructions carefully to minimize the risk of
expensive water damage.

If a

reverse osmosis water filtration system

is

connected to your cold water supply, the water

pressure to the reverse osmosis system needs to be
a minimum of 40 to 60 psi (2.8 kgf/cm^ ~ 4.2 kgf/cm^
less than 2.0~3.0sec to fill a cup of 7oz capacity).

If the water pressure from the reverse osmosis

system is less than 21 psi (1.5 kgf/cm^ more than
4.0sec to fill a cup of 7oz capacity):

Check to see whether the sediment filter in the
reverse osmosis system is blocked. Replace the
filter if necessary.

Allow the storage tank on the reverse osmosis
system to refill after heavy usage.

If the issue about water pressure from reverse

osmosis remains, call a licensed, qualified plumber.

All installations must be in accordance with local

plumbing code requirements.

NOTE:

Wear eye protection.

WHAT YOU WILL NEED

• Copper Tubing,

1/4" outer diameter

to connect the refrigerator to the
water supply. Be sure both ends of
the tubing are cut square.

To determine how much tubing you need, measure
the distance from the water valve on the back of the

refrigerator to the water supply pipe. Then add 8 feet
(2.4 m). Be sure there is sufficient extra tubing
(about 8 feet [2.4 m] coiled into 3 turns of about 10"
[25 cm] diameter) to allow the refrigerator to move

out from the wall after installation.

• A cold water supply.

The water pressure must be

between 20 and 120 p.s.i. on models without a

water filter and between 40 and 120 p.s.i. on

models with a water filter.

• Power drill.

1/2" or adjustable wrench.

Straight- and Phillips­
blade screwdriver.

Two 1/4" outer diameter
compression nuts and
2 ferrules (sleeves)

to

connect the copper tubing
to the shutoff valve and the refrigerator water valve.

' If your existing copper water

line has a flared fitting at the
end, you will need an

adapter

(available at

plumbing supply stores) to

connect the water line to the refrigerator OR you
can cut off the flared fitting with a tube cutter and
then use a compression fitting.

Shutoff valve to connect

to the cold water line.

The shutoff valve should

have a water inlet with a
minimum inside diameter

of 5/32" at the point of
connection to the COLD WATER LINE. Saddle-type
shutoff valves are included in many water supply

kits. Before purchasing, make sure a saddle-type

valve complies with your local plumbing codes.

NOTE:

Self Piercing Saddle Type Water Valve

should not be used.

28