INSTALLATION INSTRUCTIONS

m

z

o

r

(7)

FINAL INSTALLATION CHECK

Once you have completed the installation of the dryer
and it is in its final location, confirm proper operation with

the following steps and tests.

O Is gas turned ON? (Gas Models only)

0

Is dryer plugged in? Dryer should always be plugged

into the proper outlet.

Gas dryer should use a

120-VAC, 60-Hz. grounded

3-prong outlet.

Electric dryer should use

a 4-wire connection which is

required for all mobile and
manufactured home
installations, as well as

all new construction after
January 1, 1996.

- OR -

A 3-wire connection.

NOTE: A 3-wire connection
is NOT permitted on new

construction after
January 1, 1996.

O Is dryer vent ductwork connected?

O Is dryer level?

0

Perform the following tests before using the dryer.

Testing Dryer Heating

GAS MODELS

©Cl ose the dryer door.

0

Press the Power button to turn the dryer on.

0

Turn Cycle Selector Knob to Normal drying cycle.

O Press the Cycle Selector Knob to start the dryer.

When the dryer starts, the igniter should ignite the

main burner.

0

After 2 minutes, open the door and check for heat. If

no heat is felt, verify the gas valve is on and check

other gas appliances for proper operation.

NOTE:

If all air is not purged from the gas line, the gas

igniter may turn off before the main burner ignites. If this
happens, the igniter will reattempt gas ignition until all

the air is purged from the gas line.

ELECTRIC MODELS

©Cl ose the dryer door.

0

Press the Power button to turn the dryer on.

0

Turn Cycle Selector Knob to Normal drying cycle.

O Press the Cycle Selector Knob to start the dryer. The

exhaust air should be warm after the dryer has been
operating for 3 minutes.

0

After 2 minutes open the door and check for heat. If

no heat is felt, verify that BOTH breakers or fuses are
not tripped. Check for proper power cord wiring and
power supply.

Checking Venting

Vent ductwork should be checked for lint buildup
and cleaned at least once per year. If any noticeable

reduction in drying performance occurs, check ductwork

for obstructions and blockages.

Checking Leveiness

Once the dryer is in its final location, recheck the dryer

to be sure it is level. Make sure it is level front to back
and side to side, and that all 4 leveling feet rest firmly
on the floor.