SECTION 5

SERVICE TECH. INFORMATION

A. TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS
The faceplate timer (PWA) computer has a self­

diagnostic function for the electrical system, except
for input power and water meter. The computer
monitors electronic components
and circuits for correct opera­
tion. If a malfunction occurs, an
error code appears in the face­
plate display.

The chart below shows the error codes that could
appear, and the possible defects for each code.

While an error code appears in the display, all face
plate buttons are inoperable except the SELECT but­
ton. SELECT remains operational so the service per­

son can make the MANUAL INITIATED ELEC­

TRONIC DIAGNOSTICS (below) to further isolate
the defect, and check the water meter.

COÖE

POSSIBLE DEFECT

MOST LIKELY

LESS LIKELY

Erri, ЕггЗ,
Err4

motor inoperative / wiring harness or connection to switch / position switch / vaive defect causing
high torque

Err5

faceplate timer (PWA)

PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:

1. Unplug transformer from outlet 2. Correct

defect 3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.

MANUAL INITIATED ELECTRONICS
DIAGNOSTICS

To enter diagnostics, press the SELECT button

until 000 - - shows in the display.

TURBINE SWITCHES

nnn __

1Л1Ли

WATER METER (A)

------ 1

SWITCH (B)

A. The first 3 digits indicate water meter operation

as follows:

000 (steady) = Soft water not in use, and no

flow through the meter.

POSITION

SWITCH

VALVE

OUTLET

SENSOR

HOUSING

TURBINE

TURBINE

SUPPORT AND

SHAFT

—OPEN A NEARBY SOFT WATER FAUCET-

000 to 199 (continual) = Repeats display for each

gallon of water passing through the meter.

If you don't get a reading in the display, with faucet
open, puh the sensor from the valve outlet port.
Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.

B. The letter (P) and dash (or dashes) indicate

POSITION switch operation. If the letter ap­
pears, the switch is closed. If the dash shows, the

switch is open.

Use the RECHARGE button to manually ad­
vance the valve into each cycle and check correct

switch operation.