SECTION 5

SERVICE TECH. INFORMATION

A. TROUBLESHOOTING

CORRECT

SWITCH

DISPLAYS

VALVE CYCLE STATUS

Valve in service, fill, brining,

backwash or fast rinse position

„ p

Valve rotating from one position
to another

While in this diagnostic screen^ the following in­

formation is available and may be beneficial for

various reasons. This information is retained by

the computer from the first time electrical power

is applied to the face plate.

-- Press 0 to display the number of days this
face plate has had electrical power applied.

- - Press 0 to display the number of regenera­

tions initiated by this face plate since the SR code
number was entered.

Press and hold the SELECT button until...

SR17

shows.

CODE

5R I

This code identifies the softener nominal capacity

size. If the wrong number shows, the softener will
operate on incorrect programming. Do the follow­

ing as needed.

Return the present time display
LECT button.

Press the SE-

To change SR number — Press the UP or DOWN
button until the correct SR code shows. Then, press

the SELECT button and reset the timer...page 1-3.

TIMER PWA REPLACEMENT; Be sure the
valve is in service position when replacing the
timer PWA (observe valve cycle indicator).

If, after installing and programming the re­
placement timer PWA, the valve is not in ser­
vice position, do the following to assure correct
cycle orientation, or timing, between the face­
plate and valve.

Use the MANUAL ADVANCE procedures,
page 5-4. With the RECHARGE button, ad­
vance through the recharge cycles until the
valve stops in service position, and RE­
CHARGE no longer flashes in the display.

NOTE; The valve motor may automatically
drive through several valve positions while
searching for service. If an error code occurs,
unplug the transformer, then plug in again.

5 - 3

Problems, Questions? Call 1-800-426-9345 Kenmore Water Line