Leak test, Single bypass valve, Valve bypass – Kenmore 625.3835 User Manual

Page 10: Figure 13, Nstallatìon

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

nstallatìon

LEAK TEST

To check for leaks, complete the following steps:

CAUTION: To avoid water or air pressure damage to

softener inner parts, and to flush pipe chips

or other residue from the water pipes, be

sure to do the following steps exactly as

instructed.

1. Fully open two nearby cold water faucets down­

stream from the softener.

2. Place bypass valve(s) in “bypass” position (see

Figures 12 & 13). On a single valve, slide the stem

inward to bypass. On a 3-valve bypass, close the

inlet and outlet valves and open the bypass valve.

3. Fully open the house main water pipe shutoff valve.

Observe steady water flow from both open faucets.

4. Place bypass valve(s) in SERVICE, EXACTLY as fol­

lows: Keep soft water faucets open.

a. Single Bypass Valve: Slowly, slide pull the valve

stem outward toward service, pausing several times

to allow the softener to pressurize gradually.

b. 3-Valve Bypass: Fully close the bypass valve and

open the outlet valve. Slowly open the inlet valve,

pausing several times to allow the softener to pres­

surize gradually.

5. After about three minutes, open a hot water faucet

for about one minute, or until all air is expelled, then

close.

6.

Close both cold water faucets.

7. Check your plumbing work for leaks, and fix right

away if any are found. Be sure to observe previous

caution notes.

NOTE: If this procedure is performed on a new softener,

water coming from the taps may initially be dis­

colored. This normally occurs the first time

water runs through the resin bed. The discol­

ored water is not harmful, and the discoloration

will not last more than a few minutes.

SINGLE BYPASS VALVE

3-VALVE BYPASS

FOR SERVICE

Close bypass valve.

Open inlet & outlet

valves.

FOR BYPASS

Open bypass valve.

Close inlet & outlet

valves.

Outlet

Bypass

Valve

Inlet

Valve

Figure 13

Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com

10

Advertising