MANUAL ADVANCE REGENERATION CHECK

This check verifies proper operation of the valve motor,

brine tank fill, brine draw, regeneration flow rates, and

other controller functions. Always make the initial

checks first, and perform the manually initiated elec­

tronic diagnostics.

NOTE:

The display must show a steady time (not flash­

ing). If an error code shows, first press the

SELECT button to enter the diagnostic display.

1. Press the REGENERATION button and hold in for 3

seconds. “RECHARGE”, “Serv” and “Fill” begin to

flash in the display as the softener enters the fill

cycle of regeneration.

2.

When valve reaches “Fill” position, remove the

brinewell cover and, using a flashlight, observe fill

water entering the tank.

3.

If water does not enter the tank, look for an

obstructed nozzle, venturi, fill flow plug, brine tubing,

or brine valve riser pipe.

4.

After observing fill, press the REGENERATION button

to move the softener into brining. A slow flow of

water to the drain will begin. Verify brine draw

from the brine tank by shining a flashlight into the

brinewell and observing a noticeable drop in the liq­

uid level.

5.

If the softener does not draw brine:

• nozzle and/or venturi dirty

• nozzle and venturi not seated properly on gasket

• restricted drain (check drain fitting and hose)

• ineffective nozzle and venturi seal

• other inner valve problem (rotor seal, rotor & disc,

wave washer, etc.)

NOTE:

If water system pressure is low, an elevated

drain hose may cause back pressure, stopping

brine draw.

6.

Again press REGENERATION to move the softener

into backwash. Look for a fast flow of water from

the drain hose.

7.

An obstructed flow indicates a plugged top distribu­

tor, backwash flow plug or drain hose.

8.

Press REGENERATION to move the softener into fast

rinse. Again look for a fast drain flow. Allow the

softener to rinse for a few minutes to flush out any

brine that may remain in the resin tank from the

brining cycle test.

9.

To return the softener to service, press REGENERA­

TION once more.

WIRING SCHEMATIC

Back of Controller (PWA)

AC INPUT PCS./TURBINE

“ D

24 VAC

Transformer

Turbine

Sensor

ouT“

GND

+5

MOTOR

n n

grn

Valve
Motor

n

ji, NO

Position

"Tffi ® o Nc

Switch

Figure 42

Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com

22