Manually initiated electronic diagnostics, N nri и uu, Figure 38 – Kenmore 625.3835 User Manual

Page 21: Figure 39, Resetting to factory defaults, Service information, Figure 40

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Service Information

MANUALLY INITIATED ELECTRONIC DIAGNOSTICS

1. To enter diagnostics, press the SELECT button and

hold for three seconds. The display will change to

show turbine count, valve cycle position, and position

switch status (open or closed).

Valve Position

Indicator

1

Turbine Count

(No Water

Flowing)

Turbine Count

(Water Flowing)

-s- ■

n

nri

и

uu

WAm FLOW

N

/

8

7

6

5

Щ 4

Щ 3

Ш 1 #

WATCH FLOW

Position Switch

Indicator (Open)

Figure 38

Valve Outlet

Sensor

Flousing

Turbine

Turbine

Support

& Shaft

Figure 39

TURBINE OPERATION:

If no water is flowing through

the softener, the turbine indicator displays three zeros.

When water is flowing, a 000 to 199 count repeats for

each gallon of water passing through the turbine. To

check for positive operation of the turbine if zeros are

shown, open a nearby soft water faucet and observe

the turbine count. If you don’t get a reading in the dis­

play with faucet open, pull the sensor housing from the

valve outlet port (see Fig. 39). Pass a small magnet

back and forth in front of the sensor. You should get a

reading in the display. If you get a reading, unhook the

inlet and outlet plumbing and check the turbine for

binding.

POSITION SWITCH STATUS:

With the valve in service,

or any of the recharge cycle positions, the position

switch indicator will show the switch open. While the

valve is rotating from one position to another, the posi­

tion switch indicator will show the switch closed. There

is likely a problem if indications vary from this pattern.

OTHER INFORMATION:

While in the diagnostics

screen, the following information is available and may

be beneficial for various reasons. This information is

retained by the electronic controller from the first time

electrical power is applied to the unit.

• Press and hold the

A

UP button to display the num­

ber of days this controller has had electrical power

applied.

• Press and hold the

V

DOWN button to display the

number of regenerations initiated by this controller

since the model code number was entered.

NOTE:

If the electronic controller is left in the diagnos­

tic display (or a flashing display when setting

times or hardness), the normal time of day dis­

play automatically returns if a button has not

been pressed for 4 minutes. To return to the

diagnostic display, repeat step 1, above.

RESETTING TO FACTORY DEFAULTS:

To reset the electronic controller to its factory default

for all settings (time, hardness, etc.):

1. Press the SELECT button and hold it until the display

changes twice to show the flashing model code.

2.

Press the

A

UP button to display a flashing “SoS”.

Figure 40

3. Press the SELECT button, and the electronic controller

will restart.

4.

Set the present time, hardness, etc., as described on

pages 12 & 13.

Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com