Service Information

TROUBLESHOOTING

If your water softener does not work properly, make the following easy checks. Often, you will find what is wrong

yourself and you won’t have to call and wait for service. If you do not find anything wrong while making the checks,

and your softener still does not work properly, call your Sears Service Department.

PROBLEM

CAUSE

CORRECTION

No soft water

No salt in the storage tank.

Add salt and then use RECHARGE NOW

feature.

No soft water & dis­

play is blank

Transformer unplugged at wall outlet, or

power cable disconnected from back of

electronic board or transformer malfunction.

Check for loss of power and correct.

Reprogram electronic control and then use

RECHARGE NOW feature.

Fuse blown, circuit breaker tripped, or cir­

cuit switched off (see “Power Outage

Memory”).

Replace fuse, reset circuit breaker, or switch

circuit on, and then use RECHARGE NOW

feature.

No soft water & salt

level not dropping

Salt storage tank “bridged”.

Refer to “Breaking a Salt Bridge”.

Bypass valve(s) in “bypass” position.

Move bypass valve(s) to “service” position.

No soft water & salt

storage tank full of

water

Dirty, plugged or damaged nozzle & ven­

turi assembly

Take apart, clean and inspect nozzle & ven­

turi (see instruction decal under salt lid).

Valve drain hose is plugged or restricted.

Hose must not have any kinks, sharp bends or

any water flow blockage (See “Valve Drain

Requirements”).

Intermittent hard

water

Incorrect time set.

Check and change time setting.

Incorrect water hardness set.

Refer to “Set Water Hardness Number” to

set correctly.

Hot water being used when softener is

regenerating.

Avoid using hot water while the softener is

regenerating, as the water heater will fill with

hard water.

Possible increase in water hardness.

Test untreated water for hardness and iron.

Program the water softener accordingly (see

“Set Water Hardness Number”).

Brine tank flooded

Valve drain hose is plugged or restricted.

Hose must not have any kinks, sharp bends or

any water flow blockage (See “Valve Drain

Requirements”).

Dirty, plugged or damaged nozzle & ven­

turi assembly.

Take apart, clean and inspect nozzle & ven­

turi (see “Cleaning the Nozzle & Venturi”).

Salty tasting water

immediately after

regeneration

Backwash and fast rinse cycle times are not

long enough.

Increase backwash & fast rinse times (see

“Back Wash & Fast Rinse Times”).

Valve drain hose is plugged or restricted.

Hose must not have any kinks, sharp bends or

any water flow blockage (see “Valve Drain

Requirements”).

Error code appears

(example: “Err3”)

Fault in electronic controller or wiring har­

ness connections to position switch, position

switch inoperable or motor inoperable.

Unplug power cord. Check all wiring con­

nections to be sure they are secure. Plug in

power cord and wait 6 minutes. If error

code returns, call Kenmore Water Line.

Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com