INSTALLATION INSTRUCTIONS (continued)

1. Install a manual gas line shut-off valve in the gas line

in an easily accessed location outside of the range.
Make sure everyone operating the range knows where
and how to shut off the gas supply to the range.

2. Install male '/

2

" flare union adapter to the Vs" NPT

internal thread at inlet of pressure regulator.
Use a back-up wrench on the regulator fitting
to avoid darnsge.

3. Install male Vs" or W' flare union adapter to the NPT

internal thread of the manual shut-off valve, taking care
to back up the shut-off valve to keep it from turning.

4. Connect flexible metal appliance connector to the

adapter on the range. Position range to permit
connection at the shut-off valve.

5. When all connections have been made, make sure

ail range controls are in the OFF position and turn on
the main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in
the system.

WARNING

* DO NOT USE A FLAME TO

CHECK FOR GAS LEAKS.

When using test pressures greater than Vz psig to
pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from

the gas supply piping. When using test pressures of

Vz psig or less to test the gas supply system, simply
isolate the range from the gas supply system by closing

the individual shut-off valve.

PREFERRED

METHOD

Electrical Connections

(on some models)

Electrical Requirements

120-volt, 60 Hertz, properly grounded branch circuit

protected by a 15-amp or 20-amp circuit breaker or time
delay fuse.

Extension Cord Cautions

Because of potential safety hazards associated with
certain conditions, we strongiy recommend against the
use of an extension cord. However, if you still elect to use
an extension cord, it is absolutely necessary that it be a
UL-listed, 3-wire grounding-type appliance extension cord
and that the current carrying rating of the cord in amperes
be equivalent to, or greater than, the branch circuit rating.

Grounding-—IMPORTANT {Please read carefully)

FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.

The power cord of this
appliance is equipped
with a three-prong

(grounding) plug which
mates with a standard

three-prong grounding
wail receptacle to

minimize the possibility of

plpplrifi *iihnrk hi^7Arri

1

r / ■

^

iiEiULrK f

I ij insure proper

from this appliance

^ ground exists

,

...

^ before use

The customer should
have the wall receptacle
and circuit checked by a qualified electrician to make
sure the receptacle is properly grounded.

Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle,

DO NOT, UNDER ANY CiRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM THE
POWER CORD.

A word about GFCI’s - GFCTs are not required or
recommended for gas range receptacles.

Ground Fault Circuit interrupters (GFCrs) are devices that
sense leakage of current in a circuit and automatically
switch off power when a threshold leakage level is
detected. These devices must be manually reset by the
consumer. The National Eiectrical Code requires the use of
GFCi's in kitchen receptacles installed to serve countertop
surfaces. Performance of the range will not be affected if
operated on a GFCl-protected circuit but occasional

nuisance tripping of the GFCI breaker is possible.