Installation Instructions (cont’d)

Filling the Water Heater

To fill the water heater with water:

Close the water heater drain valve by turning rhe handle to

the right (clockwise). The drain valve is on the lower front of
the water heater.

Open the cold water supply valve to the water heater.
NOTE: The cold water supply valve must be left open
when the water heater is in use.

To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run

until a constant flow is obtained. This will let air out of the

water heater and the piping.

A CAUTION

Never use this water heater unless it is completely full of

water. To prevent damage to the tank and heating ele­

ment, the tank must be filled with water. Water must

flow from the hot water faucet before turning “ON"

power.________________________________________________

• Check all new water piping for leaks. Repair as needed.

Converting the Lower

Element

These instructions only cover the conversion of the convertible

element, read this entire manual before attempting to install or
operate the water healer. The water heater is factory set to oper­
ate at 3800 watts. The lower element can be converted to oper­
ate at 5500 watts. Refer to the “Facts to Consider About the

Location” section.

The Upper Element, (if a double element model) is a conven­

tional 3800 watt element which only operates at its rated

wattage on 240 volts. (See rating plate on water heater).

The Lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.

If after reading these instructions and this manual, if you do not
understand any portion, call Sears Service Center.

AWARNING

Before making the conversion to 5500 watts, check the
(I) power supply...must be 240 volts, (2) wiring... 10 gauge
AWG, Type TW, 60*C or equivalent, and (3) Circuit
breakers or fusing...capable of 30 amp loading. Also, the
installation must conform with this Manual, local codes
and electric utility rules. FAILURE TO COMPLY CAN

RESULT IN DEATH, SERIOUS BODILY INJURY OR
PROPERTY DAMAGE.

onm a

TMB

memir

*

l

-

W*rs HEHnON MODEL t

MOOH. NUMBER

^L^TRIC

HEATER

ECO

INSTALLED

SERIAL NUUaa

FACTORY EQUIPPED WITH

UPPER

LOACH

WATTS WATT6

OPTIONAL WATTAGE

U.AGAL

WXTO ÇHËCK^/)HER£'

1 Ï 150

V'fHSTft'i.'epÍ5' *-.¿1.

WATTS AC.

FIKSTALLEDAS'

. FACTOfty EQtflPPED

UAMUUW CHECK (/1 HERE ?'i

--------............WARNING

SEE CONVERSION

INSTRUCTION

WATTS. : IF CONVERTED : .

NOTE: Whether or not the element conversion is made the
model rating plate must be marked. Using a hard point ink
pen, check the appropriate block within the model rating
plate, which is located adjacent to the lower access panel.

Necessary element conversion parts are located in a small bag
contained within the electrical junction box on top of the water
heater,

CONVERSION PARTS

BUSS BAR

1. Before beginning the conversion turn “OFF” electric power

supply to the water heater.

AWARNING

HAZARD OF ELECTRICAL SHOCK! Before removing

any access panels or servicing the water heater, make

sure the electrical supply to the water heater is turned
“OFF". FAILURE TO DO THIS COULD RESULT IN
DEATH, SERIOUS BODILY INJURY, OR PROPERTY