Installation Instructions (cont’d)

Temperature-Pressure

Relief Valve

A WARNING

At the time of manufacture this water heater was provid­
ed with a combination temperature-pressures relief valve
certified by a nationally recognized testing laboratory that
maintains

periodic

inspection

of

production

of

listed

equipment or materials, as meeting the requirements for

Relief Valves and Automatic Gas Shutoff Devices for Hot

Water Supply Systems, and the latest edition of ANSI
Z2I.22 and the code requirements of ASME. If replaced,
the valve must meet the requirements of local codes, but

not less than a combination temperature and pressure
relief valve certified as meeting the requirements for
Relief Valves and Automatic Gas Shutoff Devices for Hot

Water Supply Systems, ANSI Z21.22 by a nationally recog­

nized testing laboratory that maintains periodic inspection
of production of listed equipment or materials.
The valve must be marked with a maximum set pressure
not to exceed the marked hydrostatic working pressure of
the water heater (ISO lbs./sq. in.) and a discharge capacity
not less than the water heater input rate as shown on the
model rating plate. (Electric heaters - watts divided by

1000 X 3415 equal BTU/Hr. rate.)

Your local jurisdictional authority, while mandating the use
of a temperature-pressure relief valve complying with
ANSI Z2I.22 and ASME, may require a valve model differ­
ent from the one furnished with the water heater.
Compliance with such local requirements must be satis­
fied by the installer or end user of the water heater with a

locally prescribed temperature-pressure relief valve
installed in the designated opening in the water heater in
place of the factory furnished valve.
For safe operation of the water heater, the relief valve
must not be removed from it's designated opening or
plugged.

The temperature-pressure relief valve must be installed

directly into the fitting of the water heater designated for
the relief valve. Position the valve downward and provide
tubing so that any discharge will exit only within 6 inches
above, or at any distance below the structural floor. Be
certain that no contact is made with any live electrical
part. The discharge opening must not be blocked or
reduced in size under any circumstances. Excessive length,
over 30 feet, or use of more than four elbows can cause
restriction and reduce the discharge capacity of the valve.

No valve or other obstruction is to be placed between the
relief valve and the tank. Do not connect tubing directly to

discharge drain unless a 6" air gap is provided. To prevent

bodily injury, hazard to life, or property damage, the relief

valve must be allowed to discharge water in quantities
should circumstances demand. If the discharge pipe is not

connected to a drain or other suitable means, the water

flow may cause property damage.

The Discharge Pipe:
* Must not be smaller in size than the outlet pipe size of

the valve, or have any reducing couplings or other
restriction.

• Must not be plugged or blocked.
* Must be of material listed for hot water distribution.
*

Must be installed so as to allow complete drainage of

both the temperature-pressure relief valve, and the dis­

charge pipe.

• Must terminate at an adequate drain.
• Must not have any v^ve between the relief valve and tank.

A WARNING

The temperature-pressure relief valve must be manually

operated at least once a year. Caution should be taken to
ensure that (I) no one is in front of or around the outlet
of the temperature-pressure relief valve discharge line,
and (2) the water manually discharged will not cause any
bodily injury or property damage because the water may
be extremely hot
If after manually operating the valve, it fails to complete­
ly reset and continues to release water, immediately,
close the cold water inlet to the water heater, follow the
draining instructions, and replace the temperature-pres­
sure relief valve with a new one.

HOT

COLD

CONDUIT

TEMPERATURE-

PRESSURE

RELIEF VALVE

DISCHARGE PIPE

(Do not cap or plug)

WARNING

“RELIEF VALVE OPENING”

This water heater is provided with a combination Temperature-Pressure ReM Valve listed as complying with
the standard lor Relief Valves and Automatic Gas Shutoff Devices for hM Water Suppty Systems. AN5

.22

and the code requirements of ASUE.

Vour local jurisdictiortBl authority, while mandating the use ot a Temperature-Pressure Relief Valve complying
with AN5 ¿21

-Z2

and ASME, may require a valve model ditterent from the one tumished with the water heater.

Compliance with such local requirements must be satisfied by the inslaller or end user ot the water heater with
a locally prescribed Temperature-Pressure Reliel Valve installed in the designated opening in the water

TiP RELIEF
VALVE PROBE
MUSTEXTEND

INTO TANK

TEMPERATURE-
PRESSURE

RELIEP VALVE

(tVi-

X

V.‘)

BRASS ^

NIPPLE

• II a short shank (less than 2") temperature-pressure relief valve is lo be installed

(as shown}, a ripple and coupling must be used

* If a long shartk (2" or longer) « lo be installed, do not use the mpple and coupling.

'Install Temperalure-Pressure protective equipmeni required by local codes, but nol less than a combna-
lion Temperalure-Pressure Reliel Valve cerllfied as meeting the requiremenis lor Reliel Valves and
Aulomatic Gas Shulotf Devices for Hol-Waler Supply Systems, ANS Z21

22

by a nalionally recognized test­

ing laboratory that maintains periodic tnspeclion of production of listed equipment or materials. The valve
must be oriented, provided wilh lubing, or otherwise installed so that discharge can exit only within 6 inches
above, or at any distance below the struclural floor, and cannot contact any live electrical part.*'
for sale operation ol the water heater, the Reliel Valve must not be removed or plugged
See manual heading • ‘Temperature Pressure Relief Valve” for inslallation and maintenance of Reliel
Valve, discharge pipe and other safety precautions