Converting the lower element (cont’d), Awarning, Installation instructions (cont'd) – Kenmore POWER MISER 153.316555 User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Installation Instructions (cont'd)

Converting the Lower

Element (cont’d)

2, The convertible element is located behind the lower access

panel of the water heater. Remove the two screws securing
the access panel, and remove panel.

5. Remove the screws from terminal 2 of the element, and move

the looped end of the wire aside.

3. Remove the insulation block to expose the opening.

6. The buss bar is labeled 5500 W. Place the buss bar over termi­

nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3.

4. Lower Element: Lift out the tab as shown to unclip the ter­

minal cover from the thermostat. The terminal cover can be

removed from the thermostat.

7. The wire removed from terminal 2 has a looped end. It must

remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.

8. Tighten terminals 2 and 3 to ensure proper electrical

connection.

AWARNING

Failure to tighten terminal screws can cause a fire which
can result in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.