PERFORMANCE DATA SHEET

Base Grille Water Filtration System

Model T1KB1/T1RFKB1 Capacity 100 Gallons (379 Liters)

System tested and certified by NSF internationai against NSF/ANSi Standard 42 for the reduction of

Chiorine Taste and Odor, Particuiate Ciass i*; and against NSF/ANSi Standard 53 for the reduction of
Lead, Mercury, Atrazine, Benzene, Toxaphene, 0-Dichiorobenzene, Cysts, Turbidity, Asbestos, Lindane,

Tetrachioroethyiene, Endrin, Aiachior, Chiorobenzene, Ethyibenzene, TTFIM, MTBE and VOC.

This system has been tested according to NSF/ANSi Standards 42 and 53 for the reduction of the substances iisted beiow. The

concentration of the indicated substances in water entering the system was reduced to a concentration iess than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

Chlorine Taste/Odor

50% reduction

2.0 mg/L

2.0 mg/L ± 10%

0.08 mg/L

2.0 mg/L

95.93

97.36

Particulate Class 1*

85% reduction

3533333#/mL

At least 10,000 partioles/mL 22000 #/mL"

11567 #/mL

99.38

99.67

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum %

Average %

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

Lead: @ pFI 6.5

0.010 mg/L

150 ug/L

0.15 mg/L± 10%

1.0 ug/L

1 ug/L

99.33

99.33

Lead: @ pH 8.5

0.010 mg/L

157 ug/L

0.15 mg/L± 10%

2.0 ug/L

1.08 ug/L

98.72

99.31

Mercury: @ pH 6.5

0.002 mg/L

0.0058 mg/L

0.006 mg/L ± 10%

0.0002 mg/L

0.0002 mg/L

96.53

96.53

Mercury: @ pH 8.5

0.002 mg/L

0.0057 mg/L

0.006 mg/L± 10%

0.0002 mg/L

0.0002 mg/L

96.5

96.5

Benzene

0.005 mg/L

15 ug/L

0.015 mg/L± 10%

0.5 ug/L

0.5 ug/L

96.67

96.67

O-Dichlorobenzene

0.6 mg/L

1750 ug/L

1.8 ± 10%

1.0 ug/L

1.0 ug/L

99.94

99.94

Toxaphene

0.003 mg/L

15 ug/L

0.015 ± 10%

1.0 ug/L

1.0 ug/L

93.33

93.33

Atrazine

0.003 mg/L

10 ug/L

0.009 mg/L± 10%

2 ug/L

2 ug/L

80.8

80.8

Asbestos

99%

101 MEL

10* to 10®fibers/L**

0.17 MEL

0.17 MEL

99.83

99.83

Live Cysts*

>99.95%

120,000/L

50,000/L min.

8/L*

1/L»

99.99

>99.99

Turbidity

0.5 NTU

11.4 NTU

11± 1 NTU

0.41 NTU

0.24 NTU

96.4

97.89

Aiachior

0.002 mg/L

41.3 ug/L

0.04 ± 10%

0.2 ug/L

0.2 ug/L

99.52

99.52

Endrin

0.002 mg/L

5.9 ug/L

0.006 ±10%

0.5 ug/L

0.3 ug/L

91.5

95.47

Ethylbenzene

0.7 mg/L

1867 ug/L

2.1 ± 10%

0.70 ug/L

0.0588 ug/L

99.96

100

Lindane

0.002 mg/L

1.9 ug/L

0.002 ± 10%

0.02 ug/L

0.02 ug/L

98.93

98.93

Chlorobenzene

0.6 mg/L

2.0 ug/L

2.0 ± 10%

0.0005 ug/L

0.0005 ug/L

99.98

99.98

Tetrachioroethyiene

0.005 mg/L

14.2 ug/L

0.015 ± 10%

0.5 ug/L

0.5 ug/L

96.47

96.47

TTHM

0.080 mg/L

465 ug/L

0.45 ± 20%

1.0 ug/L

0.5 ug/L

99.78

99.88

MTBE

0.005 mg/L

14 ug/L

0.015 ± 20%

0.70 ug/L

0.52 ug/L

94.94

96.27

VOC

0.015 mg/L

0.3520 mg/L

0.300 ± 10%

0.0060 mg/L

0.0008 mg/L

98.4

99.78

Test Parameters: pFI = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 100 gallons (379 liters).

It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model T1KB1: The filter monitor system measures the amount of

water that passes through the filter and alerts you to replace the

filter.

Style 1 - When the filter indicator reads 10%, order a new filter.
When the indicator reads 0%, it is recommended that you

replace the filter.

Style 2 - When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,

it is recommended that you replace the filter.

Style 3 - When the water filter status display changes from

“GOOD” to “ORDER,” order a new filter. When the filter indicator
reads “REPLACE,” it is recommended that you replace the filter.
Use replacement cartridge T1RFKB1, part #9030.
2008 suggested retail price of $59.99 U.S.A./$71.99 Canada.
Prices are subject to change without notice.

These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after the

system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.

Refer to the “Warranty” section for the Manufacturer’s name,

address and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited

warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8°C)

Service Flow Rate

0.5 gpm (1.9 L/min) @ 60 psi

‘Class I particle size: >0.5 to <1 um

"Test requirement is at least 100,000 partioles/mL of AC Fine Test Dust,

ttpibers greater than 10 um in length

♦Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.