Product data sheet, Water filtration system model nlc-250, Application guidelines/ water supply parameters – Kenmore 2200128 User Manual

Page 29

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Product Data Sheet

Water Filtration System Model NLC-250

This product has been tested and certified by NSF International under ANSI/NSF Standard 42
for Taste, Odor and Chlorine reduction (Class!) and Particulate reduction (Class

I)

and under

Standard 53 for Cyst, Turbidity, and Lead reduction.

Sp6CificationS'

Lead, Particulate (Class I), Cyst, Turbidity and Taste/Odor/Chiorine reduction (Class I)

250 Gallons (946 Liters)

Service Flow Rate 0.5 GPM (1.89 L/min) @ 60 psi

Substance

Reduction

Aesthetic Effects

Average

Influent

Maximum
Effluent

Average

Effluent

Minimum %
Reduction

Average %

Reduction

NSF Test
Requirement

Chlorine
Particulate

1.9 mg/L

610,000/mU

N/A
N/A

0.04 mg/L
154/mL

N/A
N/A

97.9%

minimum 75% reduction (Class 1)

99.97%

minimum 85% reduction (Class 1)

Substance
Reduction

U.S. EPA Average

Maximum

Average

Health Effects MCL

Influent

Effluent

Effluent

Minimum % Average %
Reduction Reduction NSF Test Requirement

Cyst

99.95%

89,250/mL 6/mL

2.3/mL

99.993%

99.997%

Turbidity

0.5 NTU

29 NTU

0.12 NTU

0.09 NTU

99.59%

99.69%

minimum 99.95% reduction
maximum effluent 1.0 NTU

Lead @ pH 6.5 0.015 mg/L 0.16 mg/L« 0.001mg/L

0.001mg/L 99.4%

99.4%

Lead @ pH 8.5 0.015 mg/L 0.16 mg/L« 0.002mg/L

0.001mg/L 98.8%

99.4%

maximum effluent 0.015 mg/L
maximum effluent 0.015 mg/L

^ Test requirement is at least 10,000 partides/mL of AC Fine Test Dust. **Test requirement is 0.15 mg/L ±10%.

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

Application Guidelines/
Water Supply Parameters

Water Supply

City or Well

Water Pressure

30-120 psi (207-827 kPa)

Water Temperature

33°-100T (0.6^-37.8“C)

NSF is a registered trademark of NSF International

' It is essential that operational, maintenance,

and filter replacement requirements be carried
out for this product to perform as advertised.

' Change cartridge at ieast every 6-9 months.

Use replacement cartridge part #NLC-250 or

#4392922. Suggested retail price of $39.95

U.S.A./S49.95 Canada.

■ The product is for cold water use only.

' Do not use with water that is microbiologically

unsafe or of unknown quality without adequate
disinfection before or after the system. Systems
certified for cyst reduction may be used on
disinfected water that may contain fiiterabie
cysts.

29