400 gallons (1514 liters), Product data sheet, Water filtration system model lc-400 – Kenmore 2200128 User Manual

Page 30: Application guidelines/ water supply parameters

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Product Data Sheet

Water Filtration System Model LC-400

This product has been tested and certified by NSF International under ANSI/NSF Standard 42
for Taste, Odor and Chlorine reduction (ClassI) and Particulate reduction (Class I) and under
Standard 53 for Cyst, Turbidity, and Lead reduction.

SpGCifiCStionS' Lead, Particulate (Class 1), Cyst, Turbidity and Taste/Odor/Chlorine reduction (Class I)

400 Gallons (1514 Liters)

Service Flow Rate 0.5 GPM (1.89 L/min) @ 60 psi

Substance
Reduction

Aesthetic Effects

Average

Influent

Maximum
Effluent

Average
Effluent

Minimum %
Reduction

Average %

Reduction

NSF Test
Requirement

Chlorine
Particulate

2.0 mg/L
610,000/mLt

N/A
N/A

0.04 mg/L

154/mL

N/A
N/A

98%
99%

minimum 75% reduction (Class I)
minimum 85% reduction (Class 1)

Substance
Reduction
Health Effects

U.S. EPA

Average

Maximum

Average

Minimum %

Average %

MCL

Influent

Effluent

Effluent

Reduction

Reduction

NSF Test Requirement

Cyst

99.95%

89,250/mL^ 6/mL

2.3/mL

99.993%

99.997%

minimum 99.95% reduction

Turbidity

0.5 NTU

29 NTU

0.12 NTU

0.09 NTU

99.59%

99.69%

maximum effluent 1.0 NTU

Lead @ pH 6.5 0.015 mg/L 0.16 mg/L+ O.OOlmg/L O.OOlmg/L 99.4%

99.4%

Lead @ pH 8.5 0.015 mg/L 0.16 mg/L^t 0.002 mg/L O.OOlmg/L 98.8%

99.4%

maximum effluent 0.015 mg/L
maximum effluent 0.015 mg/L

’ Test requirement is at least 10,000 particles/mL of AC Fine Test Dust. ” Test requirement is 0.15 mg/L ±10%.

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

Application Guidelines/
Water Supply Parameters

Water Supply

City or Well

Water Pressure

30-120 psi (207-827 kPa)

Water Temperature

33°-100T (0.6°-37.8^C)

® NSF is a registered trademark of NSF Internationai

It is essential that operational, maintenance,

and filter replacement requirements be carried
out for this product to perform as advertised.

The filter monitor system measures the amount

of water that passes through the filter and alerts
you to replace the filter. When 90% of the filter's

rated life is used, the filter indicator light changes

from green to yellow. When 100% of the filter's

rated life is used, the filter indicator light changes

from yellow to red, and it is recommended that
you replace the filter. Use replacement cartridge

part #LC-400 or #4392922. Suggested retail price

of $39.95 U.S.A/$49.95 Canada.

The product is for cold water use only.

Do not use with water that is microbiologically

unsafe or of unknown quality without adequate

disinfection before or after the system. Systems
certified for cyst reduction may be used on
disinfected water that may contain filterable
cysts.

30