Vent system chart – Kenmore 8907 User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Vent system chart

NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.

ELECTRIC AND GAS DRYER

Weather Hood Type

Recommended

Use only for short-run

installation

4 ” (1 0 .1 6 c m )

%

2 .5 ” (6 .3 5 c m )

No. of 90°

elbows

Rigid

Metallic

Flexible*

Rigid

Metallic

Flexible*

0

2 4 .4

m

(8 0 ft.)

1 2 .4 m (4 1 ft.)

2 2 .6

m

(7 4 ft.)

1 0 .1 m (3 3 ft.)

1

2 0 .7

m

(6 8 ft.)

1 1 .2 m (3 7 ft.)

1 8 .9 m (6 2 ft.)

8 .8

m

(2 9 ft.)

2

1 7 .4 m (5 7 ft.)

1 0 .1 m (3 3 ft.)

1 5 .5 m (5 1 ft.)

7 .6

m

(2 5 ft.)

3

1 4 .3 m (4 7 ft.)

9 .0

m

(2 9 ft.)

1 2 .5 m (4 1 ft.)

6 .5

m

(2 1 ft.)

Do not use non-metallic flexible duct.

Install exhaust hood. Use caulking compound to seal exterior

wall opening around exhaust hood.

Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.

Run vent to dryer location. Use the straightest path possible.

See “Determine vent path” in “Plan Vent System.” Avoid 90°
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.

METHOD1

The dryer must be connected to the cold water faucet using the

new inlet hoses. Do not use old hoses.

1. If space permits, attach the brass female end of the “Y”

connector to the cold water faucet.

2. Turn the cold water faucet

off.

3. Attach the straight end of long hose to “Y’ connector.

4. Using pliers, tighten the coupling with an additional two-

thirds turn.

{^\ Do not overtighten, as it may damage the coupling.

5. Attach angled end of long hoses to fill the valve at the

bottom of the dryer’s rear frame. Screw on coupling by hand
until it is seated on fill valve connector.

6. Using pliers, tighten the coupling with an additional two-

thirds turn.

m Do not overtighten, as it may damage the coupling.

7. Check that the water faucets are on.

8. Check for leaks around “Y” connector, faucets and hoses.

1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet

in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Check that the vent is secured

to exhaust hood with a 4" (10.2 cm) clamp.

2. Move dryer into its final location. Do not crush or kink vent.

3. (On gas models) Check that there are no kinks in the flexible

gas line.

4. Once the exhaust vent connection is made, remove the

corner posts and cardboard.

11

[BETTER]592-89075-02865 A-02_EN.indd 11

2011-03-23 ¿AAll 9:49:17

Advertising