Electrical Shock Hazard

Plug into a grounded 4 prong outlet.

Failure to do so can result in death or electrical shock.

It is your responsibility

■ To contact a qualified electrical installer.

■ To be sure that the electrical connection Is adequate and

in conformance with the Canadian Electrical Code, C22.1-
latest edition and all local codes. A copy of the above
codes standard may be obtained from: Canadian Standards
Association,

178

Rexdale Blvd., Toronto, ON

M9W 1R3

Canada.

■ To supply the required 4 wire, single phase, 120/240 volt, 60

Hz., AC only electrical supply on a separate 30-amp circuit,

fused on both sides of the line. A time-delay fuse or circuit

breaker is recommended. Connect to an individual branch
circuit.

■ This dryer is equipped with a

CSA

International Certified

Power Cord intended to be plugged into a standard 14-30R

wall receptacle. The cord is 5 ft

(1

.52

m)

in length. Be sure

wall receptacle is within reach of dryer’s final location.

GROUNDING INSTRUCTIONS

■ For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or

breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.

This dryer is equipped with a cord having an equipment­
grounding conductor and a grounding plug. The plug

must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.

WARNING:

improper connection of the equipment­

grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with the
dryer: if it will not

fit

the outlet, have a proper outlet installed

by a qualified electrician.

■ For

Gas

Models

Your Dryer has a cord with an equipment-grounding
conductor and a grounding plug.
The plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.

Do not modify the plug provided with your Dryer - if it

doesn’t fit the outlet, have a proper outlet installed by a
qualified electrician.

NEVER CONNECT GROUND WIRE TO PLASTIC PLUMBING
LINES, GAS LINES, OR HOT WATER PIPES.

SAVE THESE INSTRUCTIONS

D D

4-wire receptacle 14-30R

■ Do not use an extension cord.

If you are using a replacement power supply cord, it is
recommended that you use Power Supply Cord Replacement
Part Number DC96-00762A. For further information, please call
1-800-4-MY-HOME® (1 -800-469-4663).