Figure 23 – Caterpillar TAURUS 70 User Manual

Page 53

Advertising
background image

Turbomachinery Package Specification

Taurus

70 Compressor Set and Mechanical Drive

Figure 23. Typical Water Mist Suppression Fire Cylinder Cabinet


Table 11. Enclosure Specifications

Enclosure

Optional Ventilation Fan Motor Voltage Ratings

380 VAC, 400 VAC, and 415 VAC (50 Hz)
460 VAC (60 Hz)

Primary Enclosure Lighting Voltage

220 VAC (50 Hz) or 110 VAC (60 Hz)

Standby Enclosure Lighting Voltage

120 VDC

Sound Pressure Level

See Note (a)

Enclosure Roof Load

244 kg/m

2

(50 lb/ft

2

)

Enclosure Wind Load

193 kph (120 mph)

Approximate Measurements

Height

2.9 m (9 ft. 6 in.), Does Not Include Ventilation
Ducting

Width

2.7 m (8 ft 10 in.

Driver Length

8 m (25 ft)

Driven Length (Single Body Compressor)

4.6 m (15 ft)

Approximate Weights

Gas Turbine Enclosure

5180 kg (11,420 lb)

Compressor Enclosure (Single Body)

5670 kg (12,500 lb)

Fire Suppression System Compliance

CO

2

Fire Suppression System

U.S. National Fire Protection Association (NFPA) 12
United States Coast Guard (USCG) CFR 46

Water Mist Fire Suppression System

U.S. NFPA Code 750; USCG CFR 46

Water Mist Fire Suppression System

Minimum Operating Temperature

4°C (40°F), Optional Heater Available