Installation

Electrical Connections

ATTENTION

A qualified electrician must connect the main incoming power to the dishwasher in accordance with all

local codes and regulations or in the absence of local codes in accordance with the National Electrical

Code.

THREE PHASE

POWER CONNECTION

208-240V/60/3

LINE IN

L1

L2

L3

GRD

Standard Dishwashers are shipped from

the factory for 3-phase operation.

To connect the dishwasher for 3-phase

operation:

1. Remove the top-mounted control

cabinet cover and locate the main

terminal block in the left-rear

corner of the cabinet.

2. Refer to the

Machine Electrical

Connection Data Plate located

near the main terminal block and

make sure that the incoming

power supply matches the

machine's electrical requirements.

3. Connect the incoming 3-phase

power as shown in the illustration

to the right.

4. Re-install the control cabinet

cover.

WARNING:

Electrocution or serious injury may result when working on an

energized circuit.
Disconnect power at the main breaker or service disconnect

switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is being

performed on the circuit.

Three Phase Operation

Main Terminal Block

Main Terminal Block Location

NOTE:

Refer to the next page for 3-phase to

1-phase field conversion instructions.