Change the default system password, Webmin, Point your browser at: https://dm-ats:10000 – Comtrol DM ATS-LNX User Manual

Page 10

Advertising
background image

Installation and Setup

10

Webmin

6.

Change the default system password.

dm-ats:~# passwd
Enter new UNIX password: [

enter new_password]

Retype new UNIX password: [

retype new_password]

passwd: password updated successfully
dm-ats:~#

7.

Run the ./newsshkeys.sh shell script in the user root home directory, which
automatically generates a new SSH key.

Note: All ATS-LNX units are shipped with the same default SSH key. If you

do not change the key, somebody else will be able to decrypt your SSH
traffic.

8.

Run the ./netconfig.sh shell script in the user root home directory to configure
the network settings on the ATS-LNX. The default network settings are:

eth0: 192.168.255.252 (Ethernet #2)

eth1: 192.168.250.251 (Ethernet #1)

Note: The ATS-LNX provides Ethernet ports that function as two independent

Ethernet network interface cards.

See

Network Card Installation and Configuration

on Page 19 for

PCMCIA network configuration

9.

Edit the /etc/resolv.conf file to modify the IP address.

10. Confirm that the /etc/nsswitch.conf file contains this line:

hosts: files dns

11. Connect Ethernet cables to the ports that you configured.

12. Ping the ATS-LNX to verify proper network configuration.

Webmin

The ATS-LNX is shipped with the Webmin remote administration package

http://

www.webmin.net/

. It listens for https connections on Port 10000. If you plan on

leaving Webmin on the system, you should change the default root Webmin
password.

Use this procedure to change the root Webmin password from a remote PC.

1.

Point your browser at: https://dm-ats:10000/

where dm-ats is the IP address or host name of the ATS-LNX.

Depending on your browser, you may get a security alert and be advised that
the device does not have a security certificate.

2.

Log in as root; devicemaster is the default Webmin password and it is case-
sensitive.

PCMCIA knock-out removed,

SERIAL PORTS 1-8 connector and fanout

cable, if RocketPort PC104 option ordered.

if option ordered

eth1

eth0