background image

36

Chapter 6 - Basic Configuration Guide

sent. This secret is used for VPN using IKE Key Management.
The same secret must also be entered into the VPN Client for
the tunnel session to be successful.

v Note: STEP/STAMP is Compatible System’s proprietary tunnel nego-

tiation protocol. It can be used to allow connections from users
running older versions of the VPN Client software, but is not rec-
ommended for new users and is not covered here.

C. Click OK. You may repeat Step 8 as needed to add all

users.

9. Save the configuration to a file and download to the device.

A. From the File menu choose Save To > File. This will bring up

a file save dialog box. Name the device configuration file,
making sure that you associate the file name with the IntraPort
2/2+ and can find the file later.

B. From the File menu choose Save To > Device. This will bring

up a download configuration dialog window. Choose the
IntraPort 2/2+ if given the option. When asked if you are sure
that you want to download the configuration and restart the
device, click on the Yes button. You should see a new window
with a log of the download process. CompatiView will then
tell you that the download is complete and the device is reboo-
ting. Do not turn the IntraPort 2/2+ off during the boot process.
After the IntraPort has rebooted, users will be able to connect
with the VPN Client software.