13.6 Electric Intercooler Fan Control (IF)


This function can be used to switch on an electric fan on the intercooler when the inlet air
temperature exceeds a certain value. The fan will stay on until the temperature drops below a
second value.

Note: The electric fan cannot be driven directly by the ECU. A relay must be

used to switch the high currents drawn by the fan.


To use this function, you must have the following:

- an electric fan, fused and relay switched;
- IG5 programming software and cable.


Install the wiring for the thermofan to one of the Auxiliary outputs. This should be done in
the same way as described in figure 13.6 for the Thermofan. Be sure that the relay contacts
are rated higher than the current drawn by the fan.

Run the IG5 programming software and go to the Options page. Select the Intercooler Fan
function on the appropriate output and set the two temperatures as required.

Switch On Temperature

The inlet air temperature that must be exceed to switch the fan on.


Switch Off Temperature

The temperature the inlet air must drop below before the fan will be switched off.
This parameter should be at least 5° lower than the Switch On temperature to prevent
the fan from switching in and out repeatedly.

Figure 13.6. Example circuit for an Intercooler Fan.


13.7 Shift Light Illumination (SL)


The IG5 can be used to activate a shift light or a piezo buzzer when engine speed exceeds the
programd activation speed.