Haltech IG5 User Manual

Page 78

Advertising
background image



74

The set-up for this sensor is similar to the S1 except that one extra magnet is required as well
as the orientation being changed. The north pole of the magnet is used to generate the main
trigger while a south pole is used to generate the home or synchronisation pulse.


Typical setups (s2)


4 cylinder / 2 rotor engine

For a four cylinder 3 magnets are required in total. Two north poles positioned exactly 180

°

apart while a south pole needs to trigger the sensor before the trigger for cylinder No 1. The
positioning of the magnet for cylinder one is done the same way as the for the S1 making sure
the north pole is triggering the sensor at approximately 75

°

BTDC.













Figure 4: Typical 4 Cylinder/ 2 Rotor Application

6 cylinder engine

For a six cylinder 4 magnets are required in total. The two north poles are positioned exactly
120

°

apart while a south pole need to trigger the sensor before the trigger for cylinder No 1.













Figure 5: Typical 6 cylinder/ 3 rotor application

Advertising