Calibur Unit

Address

Camera Range

Receiver Address

Range

01

1-32

00-31

02

33-64

32-63

03

65-96

64-95

04

97-128

96-127

05

129-160

128-159

06

161-192

160-191

07

193-224

192-223

08

225-256

224-255

:

:

:

16

481-512

480-511

When more than eight Calibur units are installed, use the following formula:

Telemetry Receiver Address = 32 x (Multiplexer ID - 1) + Camera Number - 1

In other words, telemetry receiver units connected to the inputs of the first
Calibur have addresses of 0 to 31. The receivers connected to the second
Calibur have addresses of 32 to 63, and so forth.

The RS-485 network is a multi-drop wiring configuration of maximum length
3,000 feet (1000 meters). RJ-45 cable and RJ-45 connectors are used for
most hookups (see the installation/connection diagram). Some equipment
manufactured by Kalatel may use flying leads, terminal blocks, or other types
of connections.

Most units have looping RS-485 network connectors. Either socket can be
used. Do not use third-party RS-485 equipment without first consulting
Kalatel Technical Support for information on compatibility with other Kalatel
equipment.

RS-485 Wire Specification

#24 AWG, twisted pair with shield (2-wire).

Less than 16 pF per foot, nominal.

Less than 25 ohms per 100 foot, nominal.

2-wire: Belden 9842

4-wire: Belden 9844