1.5 Installation Steps Summary

Carefully and completely read the manuals for each piece of equipment
before attempting to install and connect this equipment.

Before you start connecting telemetry and other optional accessory
equipment to your system, make sure that all, power, video, VCR, and
monitor connections are completed, and everything is working correctly.

Wire the telemetry equipment according to that unit’s installation instruction.
Use the internal diagnostic testing capabilities of the telemetry receiver to
verify that the power and connections to the lens and motors are correct, and
function properly.

Using the Diagram on the following page, connect the equipment in the
following order:

1. Connect the CBR-PB2-KA2 to the Calibur unit (Multiplexer,

DVMRe, Triplex) via RS-485 port using the RJ-45 to RJ-45 cable.
The maximum total distance allowed on the RS-485 data line
(without signal amplification or modems) is 3,000 feet (1,000
meters). A 100-ohm terminator is required at each end of the
RS-485 line.

2. Supply power to the Calibur unit first and the CBR-PB2-KA2

second using the supplied AC to 12 VDC adapter. Via the Setup
Menus for the Calibur unit set the RS-485 network address to the
appropriate number (see the Appendix for RS-485 addressing).

3. Using the provided Cable connect from the ProBridge RCVR/DRVR

port to the Kalatel PTZ Interface card provided with the Cyberdome.
See the receiver's (PTZ) installation manual for more detailed
wiring instructions.

4. Set the ID addresses for the Receivers and Domes according to the

table later in this manual.

5. Via a networked connected PC with WaveReader software,

connect to the DVMRe unit and confirm proper control and
operation of the PTZ unit.