P/N 146169999-10 • REV C • ISS 02APR12

3 / 36

8

1A

1B

9A

9B

2B-3B

7B-8B

5B

4

6

1A

1B

2B

3B

4

9B

8B

7B

6

9A

5B

(3) 5 curtains

6 m range

(4) 7 curtains

6 m range

(1)

(2)

(5) 5 curtains

12 m range

(6) 7 curtains

12 m range

(7) 9 curtains

12 m range

EN: Installation Sheet

Introduction

The EV1000 series includes models EV1012 and EV1012AM.
These detectors have a patented mirror, pyro, and signal
processing technology.

Note:

EV1012AM has not been evaluated by UL/cUL.

Installation guidelines

The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Figure 1):

Direct sunlight on the detector

Strong draughts onto the detector

Heat sources within the detector field of view

Large animals within the detector field of view

Obscuring the detector field of view with large objects,
such as furniture

Objects within 50 cm (20 in.) of the anti-masking (AM)
detector

Installing two detectors facing each other and less than
50 cm (20 in.) apart

Installing the detector

Figure 7 legend

Item Description

(1)

Standard connection (factory default)

(2)

Dual loop connection

CP Control

panel

WT Walk

test

AM Antimasking

D/N Day/night

Rtest Remote

test

To install the detector:

1. Lift off the custom insert and remove the screw

(see Figure 2, item 1).

2. Using a screwdriver, carefully prise open the detector (see

Figure 2, items 2 and 3).

3. Fix the base to the wall between 1.8 m and 3.0 m (5.9 and

9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 3). To install a pry-
off tamper, use position A or B.

Note:

Using the pry-off tamper has not been evaluated by

UL/cUL.