Configuring the coverage pattern, Led indication, Specifications – Interlogix EV1012 User Manual

Page 5: Regulatory information, Ted. see “led indication

Advertising
background image

P/N 146169999-10 • REV C • ISS 02APR12

5 / 36

circuitry cannot return to its original reference levels, then
either the detector is still masked or possibly has been
damaged. The owner should then visually check that the
detector is still fully functional.

On: Resets the AM or TF status 40 seconds after a PIR alarm.

Off: Resets the AM or TF status after a PIR alarm when the
system is in Day and Walk Test status. The yellow LED will
blink quickly. When the system is in Night status, the yellow
LED will turn off and the system is reset (default).

SW 4: Signaling AM or TF output

On: Signals AM on both the AM and Alarm relays. Signals TF
on the AM relay only (EN 50131).

Off: Signals AM and TF on the AM relay (default).

SW 5: Setting LEDs

On: Enables both LEDs on the detector at all times (default).

Off: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector.

Configuring the coverage pattern

Remove blinders (Figure 8, item 1) if necessary. The
modified pattern is shown in Figure 8, items 3 to 7.

Note:

If both blinders are installed, the detector range is

limited to 6 m (default).

Modify the pattern by breaking out blinder parts (shown as
gray in Figure 8, item 1). The corresponding curtain
fragments are shown in Figure 8, item 2.

Put the appropriate mirror stickers if necessary. See
Figure 6, item 1 for details.

Caution:

Removing stickers can damage the mirror

surface.

When near objects directly under the detector, fit the mask
to the inside of the window (default). This disables the part
of the curtains looking down at the object, whose
closeness might destabilize the detector. See Figure 6,
item 2.

LED indication

PIR

Red LED

Alarm relay

To reset

Start up

Closed

Automatically after 25 s

Low voltage

Open (Alarm)

Apply correct voltage

PIR intruder
alarm

Open (Alarm)

Automatically after 3 s

PIR/AM Red

LED

Yellow
LED

Alarm
relay

AM
relay

To reset

Start up

Closed Closed Automatically

after 60 s

Low voltage

Open
(Alarm)

Open
(Alarm)

Apply correct
voltage

PIR intruder
alarm

Open
(Alarm)

Automatically

after 3 s

Latched PIR
(Memory)

Switch

to

Night

mode

PIR/AM Red

LED

Yellow
LED

Alarm
relay

AM
relay

To reset

AM alarm

Open*
(Alarm)

Open
(Alarm)

See DIP
switch 3

After AM
reset

Switch

to

Night

mode

Technical
fault

Open

(Alarm)

Do a successful
walk test

* Depends on the setting of the DIP switch SW4.

Continuously on

Normal blinking (1 Hz)

Fast (4 Hz)

Specifications

EV1012

EV1012AM

Detector

PIR

PIR + AM

Signal processing

DSP

Range 12

m

Optical

9 high-density mirror curtains

Memory No

Yes

Input power
For UL/cUL installations

9 to 15 V (12 V nominal)

10 to 15 V (12 V nominal)

Peak-to-peak ripple

2 V (at 12 V )

Detector start-up time

25 s

60 s

Normal current
consumption
For UL/cUL installations

4.4 mA

0.0528 W

10 mA

Current consumption in
alarm

1.2 mA

3.8 mA

Maximum current
consumption

11 mA

24 mA

Mounting height

1.8 m to 3.0 m (5.90 ft. to 9.84 ft.)

Target speed range

30 cm/s to 3 m/s

(1 ft./s to 10 ft./s)

20 cm/s to 3 m/s

(8 in./s to 10 ft./s)

Alarm (NC) / Tamper
relay characteristic

80 mA

30 V , resistive

80 mA

30 V

Pry-off tamper (not
evaluated by UL/cUL)

N/A Onboard

(yes)

AM relay characteristic

80 mA at 30 V max.

Alarm time

3 s

Operating temperature
For UL/cUL installations

−10 to +55°C (14 to 130°F)

0 to 49°C ( 32 to 120°F )

Dimensions (H x W x D)

108 Ч 60 Ч 46 mm (4.25 Ч 2.36 Ч 1.81 in.)

Relative humidity

95% max. noncondensing

(UL/cUL installations)

Weight

120 g (4.2 oz.)

128 g (4.5 oz.)

IP/IK rating

IP30 IK02

Regulatory information

Manufacturer UTC Fire & Security Americas Corporation, Inc.

1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA

Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands

Certification