P/N 146169999-10 • REV C • ISS 02APR12

UL/cUL

The product must be connected to a listed burglar
system compatible control unit or power supply unit,
which provides a minimum 4 hours of standby power
and has a voltage output between 10 and 15 VDC.

All wiring must be made according to National
Electrical Code, NFPA70, and CSA C22.1, Canadian
Electrical Code Part I, Safety Standards for Electrical
Installations.

Perform walk test at least one per year.

Use only a listed power-limited supply.

EV1012AM has not been evaluated by UL/cUL.

FCC

Note:

This equipment has been tested and found to

comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation.

This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment
and receiver

Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected

Consult the dealer or an experienced radio/TV
technician for help

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.

IC

This Class B digital apparatus complies with Canadian
ICES-003.

2002/96/EC (WEEE directive): Products marked with
this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper
recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more
information see: www.recyclethis.info.

Contact information

www.utcfireandsecurity.com or www.interlogix.com.

For customer support, see www.interlogix.com/customer-
support.

DA: Installationsark

Introduktion

EV1000-serien omfatter modellerne EV1012 og EV1012AM.
Disse detektorer har patenteret spejl, pyro og
signalbehandlingsteknologi.

Installationsvejledning

Den anvendte teknologi i disse detektorer er modstandsdygtig
over for falske alarmer. Undgå imidlertid mulige årsager til
ustabilitet (se Figur 1), f.eks.:

Direkte sollys på detektoren

Kraftig træk på detektoren.

Varmekilder inden for detektorens synsfelt

Store dyr inden for detektorens synsfelt

Blokering af detektorens synsfelt med store genstande
som f.eks. møbler

Genstand under 50 cm fra anti-maskeringsdetektor (AM)

Installation af to detektorer mod hinanden og mindre end
50 cm fra hinanden

Installation af detektoren

Figur 7 symbolforklaring

Punkt Beskrivelse

(1) Standardtilslutning

(fabriksstandard)

(2) Dobbelt

sløjfe-tilslutning

CP Central

WT Gangtest

AM Antimaskning

D/N Dag/nat

Rtest Fjernbetj

test

Sådan installeres detektoren:

1. Tag dækpladen af og fjern skruen (se Figur 2, pkt. 1).

2. Åbn forsigtigt detektoren med en skruetrækker (Figur 2,

pkt. 2 og 3).

3. Gør soklen fast til væggen mellem 1,8 m og 3,0 m fra

gulvet. Til fladmontering anvendes mindst to skruer
(DIN 7998) i position A. Til hjørnemontering anvendes
skruer i position B eller C (Figur 3). Til at installere
vægsabotagekontakt anvendes position A eller B.

4. Tilslut detektoren (se figur 3 og 7).

5. Vælg de ønskede jumper- og DIP-switch-indstillinger (se

figur 5). Se “Jumper-indstillinger” på side 7, hvis du ønsker
yderligere oplysninger.

6. Fjern afdækningspladerne foran spejlet og indsæt

afdækningslabel, hvis dette kræves. Se “Indstilling af
dækningsmønster” på side 8
for flere detaljer.

7. Til loftsmontering med 90 graders anvendelse benyttes

SB01-svingmonteringskonsol.

8. Luk

frontlågen.

9. Isæt skruen og anbring dækpladen.

Til EN 50131 Grade 3-installationer må monteringsposition C