SW 5: Setting LEDs

On: Enables both LEDs on the detector at all times (factory
default).
Off: Puts both LEDs under the control of the Walk Test and
Day/Night input. This activates the memory feature of the
detector.

LED indication

PIR

Red LED

Alarm relay

To reset

Start up

Closed

Automatically after 25 s

Low voltage

Open (Alarm)

Apply correct voltage

PIR intruder
alarm

Open (Alarm)

Automatically after 3 s

PIR/AM Red

LED

Yellow
LED

Alarm
relay

AM
relay

To reset

Start up

Closed Closed Automatically

after 60 s

Low voltage

Open
(Alarm)

Open
(Alarm)

Apply correct
voltage

PIR intruder
alarm

Open
(Alarm)

Automatically

after 3 s

Latched PIR
(Memory)

Switch to Night
mode

AM alarm

Open*
(Alarm)

Open
(Alarm)

See DIP
switch 3

After AM reset

Switch

to

Night mode

Technical fault

Open

(Alarm)

Do a successful
walk test

Continuously on

Normal blinking (1 Hz)

Fast blinking (4 Hz)

* Depends on the setting of the DIP switch SW4.

Specifications

EV1116

EV1116AM

Detector

PIR

PIR + AM

Signal processing

DSP

Range

16 m

Optical

11 high-density mirror curtains

Memory

Yes

Input power
For UL installations

9 to 15 VDC (12 V nominal)

10 to 15 VDC (12 V nominal)

Peak-to-peak ripple

2 V (at 12 VDC)

Detector start-up time

25 s

60 s

Normal current
For UL installations

5.5 mA

0.0528 mW

10 mA

Current in Alarm

2.5 mA

3.8 mA

Maximum current
(LED on)

11.5 mA

24 mA

Mounting height

1.8 m to 3.0 m (5.9 ft. to 9.8 ft.)

Target speed range

30 cm/s to 3 m/s

(1 ft./s to 10 ft./s)

20 cm/s to 3 m/s

(0.65 ft./s to

10 ft./s)

Alarm (NC) / Tamper relay
characteristic

80 mA 30 VDC, resistive

EV1116

EV1116AM

Pry-off tamper (not
evaluated by UL/cUL)

Optional

On-board (Yes)

AM relay characteristic

80 mA at 30 VDC

max., resistive

PIR alarm time

3 s

Operating temperature
For UL installations

−10 to +55°C (14 to 130°F)

0 to 49°C (32 to 120°F)

Dimensions (H x W x D)

125 Ч 55 Ч 60 mm

(4.92 x 2.16 x

2.36 in.)

125 Ч 65 Ч 60 mm

(4.92 x 2.6 x

2.36 in.)

Relative humidity

95% max. noncondencing

(UL Installations)

Weight

150 g

IP/IK rating

IP30 IK02

Regulatory information

Manufacturer UTC Fire & Security Americas Corporation, Inc.

1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA

Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands

Certification

UL

The product must be connected to a listed burglar
system compatible control unit or power supply unit,
which provides a minimum 4 hours of standby power
and has a voltage output between 10 and 15 VDC.
All wiring must be made according to National
Electrical Code, NFPA70, and CSA C22.1, Canadian
Electrical Code Part I, Safety Standards for Electrical
Installations.

Perform walk test at least one per year.

Use only a listed power-limited supply.

EV1116AM has not been evaluated by UL.

FCC

Note:

This equipment has been tested and found to

comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment
and receiver

Connect the equipment into an outlet on a circuit
different from that to which the receiver is
connected

Consult the dealer or an experienced radio/TV
technician for help

This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
undesired operation.

Advertising