TruVision Analog PTZ Camera

Figure 2: DIP switch settings

SW 1

SW 2

SW1 - ADDRESS

Rx Address = Switch Value

Switch1

Number

1 2 3 4 5 6 7 8

Switch1

Value

1 2 4 8 16 32 64 128

Rx Broadcast Address 0

off

off

off

off

off

off

off

off

Rx Address 1

on

off

off

off

off

off

off

off

Rx Address 255

on

on

on

on

on

on

on

on

SW2 – Baud Rate Settings

SW2 – Protocol Settings

Switch2 Number

1

2

3

Switch2 Number

4

5

6

2400 Baud

on

off

off

Interlogix/GE Impac RS-

485

off off off

4800 Baud

off

on

off

PELCO-D

on

off

off

9600 Baud

on

on

off

PELCO-P

off

on

off

19200 Baud

off

off

on

Reserved

Others

38400 Baud

on

off

on

The rest of above is 9600 Baud

Termination

Settings

Switch Number 7

Switch Number 8

Reserved

Not Terminated off

Terminated on