EN 12
TruVision Analog PTZ Camera
Figure 2: DIP switch settings
SW 1
SW 2
SW1 - ADDRESS
Rx Address = Switch Value
Switch1
Number
1 2 3 4 5 6 7 8
Switch1
Value
1 2 4 8 16 32 64 128
Rx Broadcast Address 0
off
off
off
off
off
off
off
off
Rx Address 1
on
off
off
off
off
off
off
off
Rx Address 255
on
on
on
on
on
on
on
on
SW2 – Baud Rate Settings
SW2 – Protocol Settings
Switch2 Number
1
2
3
Switch2 Number
4
5
6
2400 Baud
on
off
off
Interlogix/GE Impac RS-
485
off off off
4800 Baud
off
on
off
PELCO-D
on
off
off
9600 Baud
on
on
off
PELCO-P
off
on
off
19200 Baud
off
off
on
Reserved
Others
38400 Baud
on
off
on
The rest of above is 9600 Baud
Termination
Settings
Switch Number 7
Switch Number 8
Reserved
Not Terminated off
Terminated on