TruVision Analog PTZ Camera

Address settings

DIP switch SW1 is used to set the address of the PTZ dome. See
Table 1 below to set the PTZ camera address to a specific number.

Table 1: PTZ camera addresses

Address

1 2 3 4 5 6 7 8

0

OFF OFF OFF OFF OFF OFF OFF OFF

1

ON OFF OFF OFF OFF OFF OFF OFF

255

ON ON ON ON ON ON ON ON

Baud rate settings

Use positions 1, 2, and 3 of DIP switch SW2 to set the baud rate of the
PTZ dome. The values to select are 2400 bps, 4800 bps, 9600 bps,
19200 bps and 38400 bps. The default baud rate is 2400 bps. See
Table 2 below.

Table 2: Baud rate values

Baud

rate

1 2 3

2400 ON

OFF

OFF

4800 OFF

ON

OFF

9600

ON ON OFF

19200

OFF OFF ON

38400 ON

OFF

ON

Protocol Settings

Use positions 4, 5, and 6 of DIP switch SW2 to set the communication
protocols of the dome. See Table 3 below.

Table 3: Protocol values

Protocol 4

5

6

Interlogix-485 OFF

OFF

OFF

PELCO-D ON

OFF

OFF

PELCO OFF

ON

OFF

Reserved Others