Interlogix TruVision IP Open Standards Dome Cameras Installation Manual User Manual

Page 8

Advertising
background image

EN 8

Installation Manual

Figure 3: Connections on the base of the dome and IR dome cameras

1. Ground

Connect to ground.

2.

Ethernet RJ45 PoE port
Connect to network devices.

3. Audio

output

Connect to an audio output.
Line level, 600 Ω.

4. Initial

set

Press to reset all parameters to
factory default.

5. Audio

input

Connect to an audio input.
2.0 to 2.4 Vp-p, 1 kΩ.

6.

RS-485 D+, D-
Connect to an RS-485 device
such as a PTZ unit.

7.

Alarm outputs
Connect 1A/1B and 2A/2B to
alarm output devices.

8. Alarm

inputs

Connect IN1/GND and IN2/GND
to alarm input devices.

9. Power

supply

Connect +12 VDC power supply.

Note:

The alarm output can be used to turn on and off an external alarm device.

Connect a 12 VDC/30 mA external power supply to the alarm output. See
Figure 4 below.