Dome and ir dome camera connections – Interlogix TruVision IP Open Standards Dome Cameras User Manual User Manual

Page 11

Advertising
background image

1BChapter 2: Installation

Dome and IR dome camera connections

Note

: Do not attempt to extend the power/data cable connection using RJ45

couplers and Cat5 cable. Only use the data cable connection provided.

Note

: Use 12 VDC or PoE.

Figure 3: Connections on the base of the dome and IR dome cameras

1. Ground

Connect to ground.

2. Ethernet RJ45 PoE port

Connect to network devices.

3. Audio

output

Connect to an audio output.
Line level, 600 Ω.

4. Initial

set

Press to hard reboot camera.

5. Audio

input

Connect to an audio input.
2.0 to 2.4 Vp-p, 1 kΩ.

6. RS-485 D+, D-

Connect to an RS-485 device such as a
PTZ dome camera.

7. Alarm outputs

Connect 1A/1B and 2A/2B to alarm output
devices.

8. Alarm

inputs

Connect IN1/GND and IN2/GND to alarm
input devices.

9. Power

supply

Connect +12 VDC power supply.

Note:

The alarm output can be used to turn on and off an external alarm device.

Connect a 12 VDC/30 mA external power supply to the alarm output. See
Figure 4 below.

TruVision IP Dome Open-Standards User Manual

7