Interlogix TruPortal User Manual

Page 40

Advertising
background image

Configuring the System

28

TruPortal Software User Guide

c.

Select an Aux Relay On Time.

16.

Configure the sensor

Input Types

for:

Door Contact sensor

Request to Exit button or sensor

Aux input from the Extended Request to Exit or magnetic lock contact sensor

Tamper circuitry

Note:

The Aux and Tamper inputs listed above do not apply to doors connected to IPSDCs.

17.

Click [Accept Changes].

18.

Repeat for each door.

Configure a Door for Magnetic Locks

• WARNING! •

When configuring a door with magnetic locks, it is important to use the “Mag
Lock Bond Sense” option to prevent the door magnets from prematurely
activating and slamming the door shut, potentially causing injury.

1.

Select System Administration > Devices.

2.

Expand the tree below the System Controller.

3.

Expand the tree below the Door Controller.

4.

Select the Door to configure.

Note:

Some fields will not appear on the Devices page if a door is connected to an IPSDC,
which does not support auxiliary input/output types or tamper input points. Refer to the
IP-based Single Door Controller Quick Reference to learn about modifying jumper
settings for input types.

5.

Select a

Normal Grant Access Time

.

6.

Select an

Extended Grant Access Time

.

This is the amount of time the door will remain unlocked so the person can open it.

7.

Select a

Door Held Time

.

8.

Select an

Extended Door Held Time

.

This is the amount of time the door can remain open so the person can pass through.

9.

Select a Door Strike Mode.

Timed Unlock

Lock on Close

10.

(Optional) Select a Linked Camera if one is positioned to monitor the door.

11.

Select an

Access Mode

.

12.

(Optional) Select

Request to Exit Enabled

if the door is wired for it.

13.

(Optional) If

Request to Exit Enabled

is selected, select

Do Not Activate Strike on RTE

to

prevent the door strike from energizing when the Request to Exit contact closes.

14.

(Optional) Select any alarms the door is wired for:

Door Held Open

Door Forced Open

Tamper

15.

Select “

Mag Lock Bond Sense

” from the

Aux Input

list.

Advertising