Configuring the System

30

TruPortal Software User Guide

Do Not Activate Strike on RTE

A Request to Exit contact is typically a button located near the associated door. Select this option
to prevent the door strike from energizing when the RTE contact closes. When a cardholder
pushes the button, an RTE is sent to the System Controller. (RTEs are also known as REXs.)

If this check box is selected, the door strike will NOT energize when the RTE contact closes. If
this check box is not selected, the door strike energizes when the RTE contact closes.

Door Strike Mode

Timed Unlock

The door will unlock when access is granted and will remain unlocked until the time specified in
Normal Grant Access Time expires.

If the door Aux Input is configured for Mag Lock Bond Sense, the strike relay will remain active
until the magnetic contact sensor is active, the door contact is closed, and the door unlock time
has expired.

Note:

IPSDCs do not support Aux input and output. Schlage AD-400 wireless locks ignore
this setting.

Lock On Close

The door will unlock when access is granted and will remain unlocked until either the time
specified in Normal Grant Access Time expires, or the door is opened and closed, whichever
occurs first.

If the door Aux Input is configured for Mag Lock Bond Sense, the strike relay will remain active
until the magnetic contact sensor is active, the door contact is closed, regardless of unlock time.

Note:

IPSDCs do not support Aux input and output. Schlage AD-400 wireless locks ignore
this setting.

Access Mode

Reader In Only

The door has a reader to scan credentials for entry, but does not require a person to present a
credential to exit.

Reader In Reader Out

The door has readers to scan credentials both for entry and exit. This is required for Anti-
passback configurations.

Alarm Enabled

Door Held Open

Select this option if the door is wired to detect its opening. If held open longer than the time
selected for Door Held Time, an event will be recorded on the Events page.

Door Forced Open

Select this option if the door is wired to detect forced entry. If a person opens the door without
presenting a credential that is granted access, an event will be recorded on the Events page.
Configure with an alarm light or klaxon wired to the Aux Relay if a physical alarm should occur
if the door is forced.

Tamper

Select this option if the door is wired to detect reader tampering. If tampering occurs, an event
will be recorded on the Events page.